What are the repair parts for an SO1020M100S, series M01?
Issue:
Current design repair parts
Product Line:
Combination Service Entrance Devices
Resolution:
NOTE: WIRING DIAGRAM AND LABELS ARE NOT INCLUDED ON THE PARTS LISTED BELOW.
The parts listed here are the only parts considered field repairable:
Meter Cover Assembly - 4056180950
Meter Cover Mounting Screw - 4020513001K (contains 10 screws; only 1 required)
Load Center Cover - 4056180101
Load Center Cover Hinges - (2) X2983
Load Center Cover Hinge Mounting Screws - (2) 2159414081
Dead Front Interior Trim - 4056180001
Dead Front Interior Trim Mounting Screw - 4020513001K (contains 10 screws; only 1 required)
Load Center Interior - 4056182050 (main breaker not included)
Main Breaker - HOM2100
Main Breaker (Backfed) Retaining Bracket - 4056182101
Main Breaker Retaining Bracket Mounting Screw - 2159417121
Meter Base Assembly - 4056181950 (includes meter base, jaws, blade guides, line and load side lugs)
Meter Jaw - (4) 7329794850
Meter Jaw Mounting Keps Nut - (4) 2342702001
Meter Jaw Blade Guide - (4) 4052761901
Meter Sealing Ring - 2920910001
NOTE: WIRING DIAGRAM AND LABELS ARE NOT INCLUDED ON THE PARTS LISTED ABOVE.
Current design repair parts
Product Line:
Combination Service Entrance Devices
Resolution:
NOTE: WIRING DIAGRAM AND LABELS ARE NOT INCLUDED ON THE PARTS LISTED BELOW.
The parts listed here are the only parts considered field repairable:
Meter Cover Assembly - 4056180950
Meter Cover Mounting Screw - 4020513001K (contains 10 screws; only 1 required)
Load Center Cover - 4056180101
Load Center Cover Hinges - (2) X2983
Load Center Cover Hinge Mounting Screws - (2) 2159414081
Dead Front Interior Trim - 4056180001
Dead Front Interior Trim Mounting Screw - 4020513001K (contains 10 screws; only 1 required)
Load Center Interior - 4056182050 (main breaker not included)
Main Breaker - HOM2100
Main Breaker (Backfed) Retaining Bracket - 4056182101
Main Breaker Retaining Bracket Mounting Screw - 2159417121
Meter Base Assembly - 4056181950 (includes meter base, jaws, blade guides, line and load side lugs)
Meter Jaw - (4) 7329794850
Meter Jaw Mounting Keps Nut - (4) 2342702001
Meter Jaw Blade Guide - (4) 4052761901
Meter Sealing Ring - 2920910001
NOTE: WIRING DIAGRAM AND LABELS ARE NOT INCLUDED ON THE PARTS LISTED ABOVE.
Released for: Schneider Electric USA
Explore more
Product:
Explore more
Product:
Need help?
Product Selector
Quickly and easily find the right products and accessories for your applications.
Get a Quote
Start your sales inquiry online and an expert will connect with you.
Where to buy?
Easily find the nearest Schneider Electric distributor in your location.
Help Center
Find support resources for all your needs, in one place.