What are the repair parts for the SC816F200C, Series 001 and 002 combination service entrance device?
Issue:
Old design features
Product Line:
Combination Service Entrance Devices
Resolution:
NOTE: WIRING DIAGRAM AND LABELS ARE NOT INCLUDED ON THE PARTS LISTED BELOW.
The parts listed here are the only parts considered field replaceable and are still available:
Ring type meter socket cover - 4056127952
Load Center Cover - 4056128052 (includes hinges)
Utility/Pull Box cover - 4056133952
Deadfront Trim - 7329421701
Load Center Interior - 4056133352
Mounting screws for Meter cover and Deadfront - 4020513001K (contains 10 screws)
Mounting Rivets for Load Center Cover - 2430315290 (4 required)
Mounting screws for Load Center interior - 2142217101 (2 required)
Meter socket phenolic base with load side lugs for the main breaker wires and load side meter jaws - 4056149452 (line side meter jaws and all blade guides not included)
Meter base mounting screw - 2153217161 (1 required)
Line Side Meter Socket jaws - 7329794850
Mounting nuts for Line side Meter socket jaws - 2342702001 (1 per jaw)
Blade guides for meter socket jaws - 4052761901 (1 per jaw)
Main Line Lug - 4025116051 (1 required per phase)
Mounting bolt and nut for main lugs - 2271020242 (bolt; 1 required per lug) and 2342702000 (nut; 1 required per lug)
Hold down bolt, bracket and spacer for Main Breaker - 2159417721 (bolt), 4056152501 (bracket), and 4056152601 (spacer)
Hold down Strap for Main Breaker - 4056132701
Main Breaker - HOM2200
Old design features
Product Line:
Combination Service Entrance Devices
Resolution:
NOTE: WIRING DIAGRAM AND LABELS ARE NOT INCLUDED ON THE PARTS LISTED BELOW.
The parts listed here are the only parts considered field replaceable and are still available:
Ring type meter socket cover - 4056127952
Load Center Cover - 4056128052 (includes hinges)
Utility/Pull Box cover - 4056133952
Deadfront Trim - 7329421701
Load Center Interior - 4056133352
Mounting screws for Meter cover and Deadfront - 4020513001K (contains 10 screws)
Mounting Rivets for Load Center Cover - 2430315290 (4 required)
Mounting screws for Load Center interior - 2142217101 (2 required)
Meter socket phenolic base with load side lugs for the main breaker wires and load side meter jaws - 4056149452 (line side meter jaws and all blade guides not included)
Meter base mounting screw - 2153217161 (1 required)
Line Side Meter Socket jaws - 7329794850
Mounting nuts for Line side Meter socket jaws - 2342702001 (1 per jaw)
Blade guides for meter socket jaws - 4052761901 (1 per jaw)
Main Line Lug - 4025116051 (1 required per phase)
Mounting bolt and nut for main lugs - 2271020242 (bolt; 1 required per lug) and 2342702000 (nut; 1 required per lug)
Hold down bolt, bracket and spacer for Main Breaker - 2159417721 (bolt), 4056152501 (bracket), and 4056152601 (spacer)
Hold down Strap for Main Breaker - 4056132701
Main Breaker - HOM2200
Released for: Schneider Electric USA
Explore more
Category:
Explore more
Category:
Need help?
Product Selector
Quickly and easily find the right products and accessories for your applications.
Get a Quote
Start your sales inquiry online and an expert will connect with you.
Where to buy?
Easily find the nearest Schneider Electric distributor in your location.
Help Center
Find support resources for all your needs, in one place.