What are the repair parts for RC2040M200C, series M01?
Issue:
RC2040M200C Series M01 field replaceable parts.
Product Line:
Load Center
Environment:
Combination Service Entrance Device
Cause:
Maintenance
Resolution:
NOTE: WIRING DIAGRAM AND LABELS ARE NOT INCLUDED ON THE PARTS LISTED BELOW.
The parts listed here are the only parts considered field replaceable:
Meter Cover - 4056167850 (includes latch)
Load Center Cover - 4056157550 (includes hinges and latch)
Load Center Cover Mounting Screws - (4) 2159417121
Dead Front Interior Trim - 4056173901
Dead Front Interior Trim Mounting Screws - 4020513001K (this kit contains 10 screws; only 2 screws are required to mount the interior trim)
Load Center Interior - 4056162050 (does not include main breaker)
Load Center Interior Mounting Screws - (6) 2153217161
Main Breaker - QOM2200VH, Mounting Hardware - (2) 2342702001 Keps Nuts
Meter Base Assembly - 4056190150 (includes meter base, line side lugs, line and load side meter jaws, line and load side meter jaw blade guides, and load side connector bussing)
Meter Jaw - (4) 7329794850 (included in meter base assembly)
Meter Jaw Mounting Keps Nuts - (4) 2342702001 (included in meter base assembly)
Meter Jaw Blade Guide - (4) 4052761901 (included in meter base assembly)
NOTE: WIRING DIAGRAM AND LABELS ARE NOT INCLUDED ON THE PARTS LISTED ABOVE.
RC2040M200C Series M01 field replaceable parts.
Product Line:
Load Center
Environment:
Combination Service Entrance Device
Cause:
Maintenance
Resolution:
NOTE: WIRING DIAGRAM AND LABELS ARE NOT INCLUDED ON THE PARTS LISTED BELOW.
The parts listed here are the only parts considered field replaceable:
Meter Cover - 4056167850 (includes latch)
Load Center Cover - 4056157550 (includes hinges and latch)
Load Center Cover Mounting Screws - (4) 2159417121
Dead Front Interior Trim - 4056173901
Dead Front Interior Trim Mounting Screws - 4020513001K (this kit contains 10 screws; only 2 screws are required to mount the interior trim)
Load Center Interior - 4056162050 (does not include main breaker)
Load Center Interior Mounting Screws - (6) 2153217161
Main Breaker - QOM2200VH, Mounting Hardware - (2) 2342702001 Keps Nuts
Meter Base Assembly - 4056190150 (includes meter base, line side lugs, line and load side meter jaws, line and load side meter jaw blade guides, and load side connector bussing)
Meter Jaw - (4) 7329794850 (included in meter base assembly)
Meter Jaw Mounting Keps Nuts - (4) 2342702001 (included in meter base assembly)
Meter Jaw Blade Guide - (4) 4052761901 (included in meter base assembly)
NOTE: WIRING DIAGRAM AND LABELS ARE NOT INCLUDED ON THE PARTS LISTED ABOVE.
Released for: Schneider Electric USA
Explore more
Product:
Explore more
Product:
Need help?
Product Selector
Quickly and easily find the right products and accessories for your applications.
Get a Quote
Start your sales inquiry online and an expert will connect with you.
Where to buy?
Easily find the nearest Schneider Electric distributor in your location.
Help Center
Find support resources for all your needs, in one place.