8965 Type R hoist contactor Auxiliary contact part numbers

Issue:
What is the part # for an aux contact used on 8965RO Hoist Contactor?

Product Line:
Contractors and Starters

Environment:
North American Products

Resolution:
Yes, order the 9999R10 for normally open or 9999R11 for normally closed. The contact blocks mount between the forward and reversing contactors. You can only install 1 contact block per 8965RO10 device. The 9999R blocks actually contain either 2 NO or 2 NC contacts in the module, one for each side of the device.