What is the difference between ZBRRC, ZBRRA, and ZBRRD?

Issue:
Functions and mode of ZBRRC, ZBRRA, and ZBRRD

Product Line:
Push Buttons and Operator Interface

Environment:
XB5R Wireless Push Buttons

Cause:
Product Selection

Resolution:
ZBRRC has 4 programmable PNP outputs rated at 200mA. The ZBRRA and ZBRRD has 2 programmable relay outputs and is rated at 3A.
ZBRRC - momentary (monostable)
ZBRRD - Can be programmed for momentary (monostable), or maintained (bi-stable).
ZBRRA - Can be programmed for momentary (monostable), maintained (bi-stable), Stop/start