How can I read a string data from OFS V3.60?

Article available in these languages:

Issue:

How can I read a string data from OFS V3.60?

Product Line:

OFS

Resolution:

1) The typical syntax AliasName!%MW returns the numerical value of the string.
image

2) To see the actual data in a string format you need to add the ;c at the end.
AliasName!%MemoryWord;c

M340!%MW10:4;c
image2

If this FAQ did not solve your issue, you can chat with us at chat with us or e-mail us at customer.services@se.com to create a case with our Technical Support Team.