Do we offer a padlock attachment for a 9001KR9R that doesn't hold the button depressed?
Issue:
Customer wants a padlock attachment for a 9001KR9R that doesn't hold the button depressed.
Product Line:
9001K/ 9001KS
Environment:
9001K/ 9001KS 30mm operators emergency stop
Cause:
For a particular application, the E-stop needs to be locked out to prevent being accidental engaged.
Resolution:
Schneider Electric does not offer a padlock attachment that will not hold an e-stop in the depressed position. The emergency stop button needs to be accessible to push in case of emergency. The only option Schneider electric can offer is a guard that will protect the button against accidental operation.