How to convert a 9001 Type K/SK momentary push button operators to maintained?

Issue:
Is there a module to make the momentary 9001 type K or SK push button operators to maintained?

Product Line:
Class 9001 Type K/SK Momentary Pushbuttons

Environment:
Class 9001 Type K/SK momentary push button operators with maintained contacts.

Cause:
Help clarify how to order a push on/ push off operator.

Resolution:
Use the 9001K85 Push On/Push Off module to convert the momentary push button to maintained. Be aware that they must use the early closing NO contacts like the 9001KA4 or 9001KA6