How do I troubleshoot a residential EV charging station, EV230WS?

Issue:
An EV station is showing a detected fault indicator lamp lit.

Product Line:
PTEVC - Electrical Vehicle

Resolution:
The EVlink charging station detects several different types of faults. For residential (indoor) rated stations, the HMI (human machine interface) has 8 LED segments. Each of these segments, when lit red, indicates a different detected fault. Many conditions can be reset by powering the unit off by turning off the supplying 40 A circuit breaker.
Residential HMI Showing Segment 1 Detected Fault Lit
LED dial
EVlink Detected Faults
ResidentialDetected FaultAction
Segment 1 CCID system errorSee FA239096
Segment 2 Supply voltage errorVerify that the supply voltage between L1 and L2 is 208 to 240 VAC.
Segment 3 Main contact error (1)
Segment 4 Main contact error (2)
Segment 5 Vehicle requesting ventilationWait for call to cool.  Try charging again in 1 hour.
Segment 6 Invalid state
Segment 7Ground fault detected Unplug/re-plug vehicle
Segment 8Supply side ground not connected properlyWait for automatic reset or unplug/re-plug vehicle,  See FA268433

Schneider Electric USA

Explore more
Product:
Users group

Discuss this topic with experts

Visit our community and get advice from experts and peers on this topic and more
Explore more
Product:
  • Help Center
  • Contact Sales
  • Find our Offices
  • Where to Buy
  • Tech Support: 877-342-5173
  • Careers
  • Company Profile
  • Investors
  • Newsroom
  • Report a Misconduct
  • Product Documentation
  • Software and Firmware
  • Product Selector
  • Product Replacement
  • DigestPLUS Online Catalog
  • Industries
  • Partners
  • Schneider Electric Community
  • Events
  • Privacy Policy
  • Cookie Notice
  • Terms of use
  • Change your cookie settings