How can we help you today?
How to reset the password of the FlexNet Publisher back to default
Issue
The FlexNet Publisher (FNP) is a web interface hosted on the PME server for configuring licensing components.
The URL is https://schneider-electric.flexnetoperations.com/
The default username and password for FlexNet Publisher (FNP) is admin/admin.
If the password is changed to something else, the default admin/admin combination will not work.
Product Line
Power Monitoring Expert 7.2.x
Power Monitoring Expert 8.x
NOTE: Does NOT apply to PME 9.0 and greater
Environment
FlexNet Publisher
Cause
The default password has been changed (admin is the default password).
Resolution
*Warning: Take backups of any files prior to modifying them. Ensure the backups are in a location that will not be overwritten (i.e. the Desktop).
Following the procedure below, the password of the FlexNet Publisher can be reset to its default: "admin" (without the quotation mark).
- Navigate to:
On Power Monitoring Expert 7.2.x:
C:\Program Files (x86)\Schneider Electric\Power Monitoring Expert\Floating License Manager\FLEXnet Publisher License Server Manager\conf
On Power Monitoring Expert 8.x
C:\ProgramData\Schneider Electric\Floating License Manager\FLEXnet Publisher License Server Manager\conf
- Open the 'server.xml' in Notepad or any suitable XML editor.
- Search for: lastName="Administrator"
- Replace the contents of the password field as shown below:
id="admin" lastName="Administrator" password="(ENC-01)AxlKxBaCLbp4iPFsjJ6eOFtE+qoJWH8ThHIKN9DgdEgILS9j" passwordExpired="false"
For example if you want to change the password back to admin, here is what the line would look like:
id="admin" lastName="Administrator" password="admin" passwordExpired="false"
- Restart the "lmadminSchneider" service from 'Services'.
- Login to the Flexnet Publisher by navigating to https://schneider-electric.flexnetoperations.com/ and clicking on 'Administration'. Use the following credentials to sign in if the password was changed to "admin" on step 4:
Username: admin
password: admin
Note: The username is always "admin."
Released for: Schneider Electric USA
Explore more
Range:
Explore more
Range:
Need help?
Product Selector
Quickly and easily find the right products and accessories for your applications.
Get a Quote
Start your sales inquiry online and an expert will connect with you.
Where to buy?
Easily find the nearest Schneider Electric distributor in your location.
Help Center
Find support resources for all your needs, in one place.