What are the repair parts for the RC3040M200SL Series M01?
Issue:
Current design repair parts
Product Line:
Combination Service Entrance Devices
Environment:
Repair parts
Cause:
Maintenance
Resolution:
NOTE: WIRING DIAGRAM AND LABELS ARE NOT INCLUDED ON THE PARTS LISTED BELOW.
The parts listed here are the only parts considered field replaceable:
Meter Cover - 7329431450 (Includes latch)
Load Center Cover - 7329421550 (Includes hinges)
Load Center Cover Mounting Screws - (4) 2159417121
Dead Front Interior Trim - 7329421401
Dead Front Interior Trim Mounting Screws - 4020513001K (This kit contains 10 screws. Only 2 screws are required to mount the interior trim)
Load Center Interior - 4056184950 (Does not include main breaker, see Main Breaker below)
Load Center Interior Mounting Screws - (8) 2153217161
Main Breaker - QOM2200VH, Mounting Hardware - (2) 2342702001 Keps Nuts
Lever Bypass Meter Socket Assembly and Mounting Pan - 7329442050 (Includes the complete lever bypass meter socket and mounting pan)
Load Side Meter Socket Bus Connectors - 7329441350 (this part number is the same for both the A and B phase and attaches to the load side of the meter socket)
Keps Nuts for Load Side Meter Socket Bus Connectors - (2) 2342702400 (attaches the bus connectors to the load side of the meter socket assembly)
Main Circuit Breaker Bus Connectors - 7329441401 (this part number is the same for both the A and B phase. These connectors attach to the above load side meter socket bus connectors and to the line side of the main breaker)
Keps Nuts for Main Circuit Breaker Bus Connectors - (2) 2342702001 (connects the load side meter socket bus connectors to the main circuit breaker bus connectors).
Load Center Cover Latch - 4056314701 (this is the latch that attaches to the side of the enclosure for the load center cover)
Rivet for load center cover latch - 2410712140 (rivet used to attach the LC Cover latch to the side of the enclosure)
NOTE: WIRING DIAGRAM AND LABELS ARE NOT INCLUDED ON THE PARTS LISTED ABOVE.
Current design repair parts
Product Line:
Combination Service Entrance Devices
Environment:
Repair parts
Cause:
Maintenance
Resolution:
NOTE: WIRING DIAGRAM AND LABELS ARE NOT INCLUDED ON THE PARTS LISTED BELOW.
The parts listed here are the only parts considered field replaceable:
Meter Cover - 7329431450 (Includes latch)
Load Center Cover - 7329421550 (Includes hinges)
Load Center Cover Mounting Screws - (4) 2159417121
Dead Front Interior Trim - 7329421401
Dead Front Interior Trim Mounting Screws - 4020513001K (This kit contains 10 screws. Only 2 screws are required to mount the interior trim)
Load Center Interior - 4056184950 (Does not include main breaker, see Main Breaker below)
Load Center Interior Mounting Screws - (8) 2153217161
Main Breaker - QOM2200VH, Mounting Hardware - (2) 2342702001 Keps Nuts
Lever Bypass Meter Socket Assembly and Mounting Pan - 7329442050 (Includes the complete lever bypass meter socket and mounting pan)
Load Side Meter Socket Bus Connectors - 7329441350 (this part number is the same for both the A and B phase and attaches to the load side of the meter socket)
Keps Nuts for Load Side Meter Socket Bus Connectors - (2) 2342702400 (attaches the bus connectors to the load side of the meter socket assembly)
Main Circuit Breaker Bus Connectors - 7329441401 (this part number is the same for both the A and B phase. These connectors attach to the above load side meter socket bus connectors and to the line side of the main breaker)
Keps Nuts for Main Circuit Breaker Bus Connectors - (2) 2342702001 (connects the load side meter socket bus connectors to the main circuit breaker bus connectors).
Load Center Cover Latch - 4056314701 (this is the latch that attaches to the side of the enclosure for the load center cover)
Rivet for load center cover latch - 2410712140 (rivet used to attach the LC Cover latch to the side of the enclosure)
NOTE: WIRING DIAGRAM AND LABELS ARE NOT INCLUDED ON THE PARTS LISTED ABOVE.
Released for: Schneider Electric USA
Explore more
Product:
Explore more
Product:
Need help?
Product Selector
Quickly and easily find the right products and accessories for your applications.
Get a Quote
Start your sales inquiry online and an expert will connect with you.
Where to buy?
Easily find the nearest Schneider Electric distributor in your location.
Help Center
Find support resources for all your needs, in one place.