What are the repair parts for the SC3042M200PF, Series M01?
Issue:
Current Design Repair Parts
Product Line:
Combination Service Entrance Devices
Resolution:
NOTE: WIRING DIAGRAM AND LABELS ARE NOT INCLUDED ON THE PARTS LISTED BELOW.
The parts listed here are the only parts considered field repairable:
Meter Cover Assembly - 4053442852
Meter Cover Mounting Screw - 4020513001K (contains 10 screws, but only one screw is required)
Branch Wiring Gutter Cover (Below Meter Cover) - 4056178101
Branch Wiring Gutter Cover Mounting Screw - 4020513001K (contains 10 screws, but only one screw is required)
Utility Pullbox Cover - 4056181150 (includes cover latch)
Utility Pullbox Cover Sealing Screw - X1299
Load Center Cover Assembly - MTR10570 (Includes hinges)
Load Center Cover Mounting Screws - 2142217101 (2 required)
Dead Front Interior Trim - EAV67728 (labels not included)
Dead Front Interior Trim Mounting Screw - 4020513001K (contains 10 screws, but only two screws are required)
Load Center Interior - MTR10002 (main breaker and large branch neutral lugs not included)
Load Center Interior Mounting Screw - 4020510001 (2 required)
Main Breaker - QOM2200VH
Main Breaker mounting keps nut - 2342702001 (2 required)
Meter Base - 4054102503 (phenolic base only; phase jaws not included)
Meter Base Mounting Screw - 2142717200
Meter Socket Jaw - 7329794850 (4 required for complete meter socket; blade guides not included)
Meter Jaw Mounting Keps Nut - 2342702001 (one PER meter jaw)
Meter Jaw Blade Guide - 4052761901 (one PER meter jaw)
Meter Jaw with Blade Guide - 7329746450 (4 required for complete meter socket; includes blade guide)
Meter Sealing Ring - 2920910001
Left Line Side Phase Lug - 4025116051
Left Line Side Phase Lugs Mounting Bolt - 2271020242
Left Line Side Phase Lugs Mounting Keps Nut - 2342702001
NOTES:
1) WIRING DIAGRAM AND LABELS ARE NOT INCLUDED ON THE PARTS LISTED ABOVE
2) The device comes standard with FIVE large branch neutral lugs; (2) LK70AN, (1) 4025130250, (1) LK100AN, and (1) LK125AN
Current Design Repair Parts
Product Line:
Combination Service Entrance Devices
Resolution:
NOTE: WIRING DIAGRAM AND LABELS ARE NOT INCLUDED ON THE PARTS LISTED BELOW.
The parts listed here are the only parts considered field repairable:
Meter Cover Assembly - 4053442852
Meter Cover Mounting Screw - 4020513001K (contains 10 screws, but only one screw is required)
Branch Wiring Gutter Cover (Below Meter Cover) - 4056178101
Branch Wiring Gutter Cover Mounting Screw - 4020513001K (contains 10 screws, but only one screw is required)
Utility Pullbox Cover - 4056181150 (includes cover latch)
Utility Pullbox Cover Sealing Screw - X1299
Load Center Cover Assembly - MTR10570 (Includes hinges)
Load Center Cover Mounting Screws - 2142217101 (2 required)
Dead Front Interior Trim - EAV67728 (labels not included)
Dead Front Interior Trim Mounting Screw - 4020513001K (contains 10 screws, but only two screws are required)
Load Center Interior - MTR10002 (main breaker and large branch neutral lugs not included)
Load Center Interior Mounting Screw - 4020510001 (2 required)
Main Breaker - QOM2200VH
Main Breaker mounting keps nut - 2342702001 (2 required)
Meter Base - 4054102503 (phenolic base only; phase jaws not included)
Meter Base Mounting Screw - 2142717200
Meter Socket Jaw - 7329794850 (4 required for complete meter socket; blade guides not included)
Meter Jaw Mounting Keps Nut - 2342702001 (one PER meter jaw)
Meter Jaw Blade Guide - 4052761901 (one PER meter jaw)
Meter Jaw with Blade Guide - 7329746450 (4 required for complete meter socket; includes blade guide)
Meter Sealing Ring - 2920910001
Left Line Side Phase Lug - 4025116051
Left Line Side Phase Lugs Mounting Bolt - 2271020242
Left Line Side Phase Lugs Mounting Keps Nut - 2342702001
NOTES:
1) WIRING DIAGRAM AND LABELS ARE NOT INCLUDED ON THE PARTS LISTED ABOVE
2) The device comes standard with FIVE large branch neutral lugs; (2) LK70AN, (1) 4025130250, (1) LK100AN, and (1) LK125AN
Released for: Schneider Electric USA
Explore more
Category:
Explore more
Category:
Need help?
Product Selector
Quickly and easily find the right products and accessories for your applications.
Get a Quote
Start your sales inquiry online and an expert will connect with you.
Where to buy?
Easily find the nearest Schneider Electric distributor in your location.
Help Center
Find support resources for all your needs, in one place.