How can we help you today?
Chrome constantly prompts users with "Install Silverlight" screen.
Issue:
When attempting to view webpages in Chrome users are constantly prompted with the "Install Silverlight" screen.
Product:
EEM 4.0 R2, EEM 5.0
Struxureware Power Monitoring 7.0.x
Power Monitoring Expert 7.2.x
Power Monitoring Expert 8.0
Environment:
Chrome 42.x
EEM 4.0 R2, EEM 5.0
Struxureware Power Monitoring 7.0.x
Power Monitoring Expert 7.2.x
Power Monitoring Expert 8.0
Cause:
With the release of Chrome 42 (released Apr 14/15) Silverlight is moving closer to becoming unsupported. Chrome 42 disables by default the NPAPI API on which Silverlight runs in the browser, requiring users to re-enable the API if they wish to use Silverlight content in Chrome. It's expected that support for NPAPI will be removed in a future version of Chrome altogether.
The update for Chrome 42 is an automatic process. The patch is automatically download and applied with the next close/open of Chrome after April 15.
After the update, Silverlight will not function at all (by default).
Resolution:
*Warning: This article contains information about editing the registry. Improper changes to the registry can permanently damage the operating system. Always backup the registry before making any changes.*
The following registry key needs to be inserted or changed as follows:
[HKEY_LOCAL_MACHINE\SOFTWARE\Policies\Google\Chrome\EnabledPlugins] "1"="java"
This can be accomplished in several ways.
Method 1:
-
In Chrome, enter the following in the navigation bar: chrome://flags/#enable-npapi
-
Look for the following entry: Enable NPAPI Mac, Windows (Enables the use of NPAPI plugins. #enable-npapi) (should be highlighted at the top)
-
Click "Enable"
-
A toolbar at the bottom of the page will ask to re-launch the browser.
-
Once this re-launch occurs, all will work as before (but the user must re-install Silverlight)
Method 2:
Using Command Prompt cmd.exe (as administrator) execute the following command:reg add HKLM\software\policies\google\chrome\EnabledPlugins /v 1 /t REG_SZ /d java
Method 3:
regedit.exe (as administrator)Navigate the registry, creating the keys as necessary. Inside EnabledPlugins, create a new REG_SZ value with name 1 and value java.
*NOTE: Also by using typical enterprise policy tools an administrator could insert this registry key into all the machines on a domain.
Released for: Schneider Electric USA
Explore more
Range:
Explore more
Range:
Need help?
Product Selector
Quickly and easily find the right products and accessories for your applications.
Get a Quote
Start your sales inquiry online and an expert will connect with you.
Where to buy?
Easily find the nearest Schneider Electric distributor in your location.
Help Center
Find support resources for all your needs, in one place.