How can we help you today?

Video: PowerLogic PM8000 series meter custom screens

Issue
While setting up the custom screens for the PowerLogic PM8000 series meter, the warning "No compatible registers" is shown when the power meters module is expanded as shown in the screen shot:

ION setup

Product Line
PowerLogic PM8000 series meter

Environment
PM8000, ION Setup v3.0

Cause
On an older version of ION Setup v3.0, "Show all registers" might have been selected. This may result in the inability to select a parameter - making it difficult to create a custom screen for the PM8000 series meter.

Resolution
Ensure that the system is running the latest version of ION Setup 3.2.23186.01. (https://www.se.com/us/en/download/document/ION_Setup_Latest_Release/ )

To setup custom screens within the ION Setup Basic Configuration (Setup Assistant):
  1. Run ION Setup, select the PM8000 meter required and open 'Setup Assistant'.
ION setup
  1. Navigate to the 'Custom Displays' tab, select 'Custom Displays' and click Edit.
ION setup
  1. The display editor window should appear allowing the user to create or edit screens.
ION setup
  1. Select the desired screen and click edit to modify the screen type, parameters and digit display properties.
ION setup
  1. Within the 'Step 2: Select Parameters', click Edit and ensure that "Show all available registers" is unchecked. Expand the measurement type, select the applicable parameter, click OK and Send in the display setup window.
ION setup

To setup custom screens within the ION Setup Advanced Configuration:
  1. Right-click on the meter device in the ION Setup window and select properties. Within the device properties window, select the 'Tools' tab and change the 'Device Setup' to 'Show Advanced ION Setup' in the drop-down list and click OK. As a shortcut, you may also hold down the 'CTRL' key and click on the meter.
  2. Select the 'Display Modules' from the PM8000 modules list and right-click to create a new module within the folder.
  3. Each custom screen can display up to 6 parameters. Highlight a source in the Inputs tab and click Edit to select a parameter from one of the modules.
ION setup
  1. Click on the 'Setup Registers' tab to adjust the screen title, resolution, number and last digit mode as shown below. Once done, click send.
ION setup
IFrame

Schneider Electric USA

Explore more

Discuss this topic with experts

Visit our community and get advice from experts and peers on this topic and more

Explore more

Need help?

Product Selector

Quickly and easily find the right products and accessories for your applications.

Get a Quote

Start your sales inquiry online and an expert will connect with you.

Where to buy?

Easily find the nearest Schneider Electric distributor in your location.

Help Center

Find support resources for all your needs, in one place.