What is "+/- Speed Around Reference" on the ATV61 or ATV71 drive?
Resolution:
The +/- Speed Around Reference function allows the drive to operate at a speed that is either above or below a main speed reference by applying an adjustable offset to the reference value.
This feature is useful when multiple drives need to follow the same speed command while operating at slightly different speeds. For example, in a conveyor system, two drives may receive the same reference signal, but one conveyor may need to run slightly faster or slower than the other to maintain proper product flow.
The function works by adding to or subtracting from the primary speed reference rather than requiring a separate speed command source. This simplifies system design and improves coordination between drives.
Consult the ATV61 or ATV71 programming manual for details.
If this article does not answer your question, check out our FAQ database that has answers to more commonly asked questions:
Frequently Asked Questions - Schneider Electric (se.com)
If this FAQ did not solve your issue, you can call us at 1-888-778-2733 Option 2 and then 4 or e-mail us atdrive.products.support@se.comto create a case with our Technical Support Team.
If you are not located in North America, please contact your local Customer Care Center for assistance:
Released for: Schneider Electric USA
Explore more
Range:
Explore more
Range:
Need help?
Product Selector
Quickly and easily find the right products and accessories for your applications.
Get a Quote
Start your sales inquiry online and an expert will connect with you.
Where to buy?
Easily find the nearest Schneider Electric distributor in your location.
Help Center
Find support resources for all your needs, in one place.