How can we help you today?
Is there a compatibility list of firmware for PL7 Micro/Premium processors?
Issue:
Is there a compatibility list of firmware for PL7 Micro/Premium processors?
Product Line:
TSXP57, TSX Premium, TSX37, TSX Micro, PL7, Firmware
Resolution:
Below is the compatibility table of firmware for the TSX Micro and Premium controllers:
TSX Micro hardware bases
---------------------------
Processor type PV Compatible operating systems versions
TSX3710000 =08 SV1.7
TSX3721000 =07 SV1.7
TSX3722000 =07 SV1.7
TSX3705001 <=06 SV3.5, SV4.0, SV5.0, SV5.1, SV6.0
TSX3708001 <=06 SV3.5, SV4.0, SV5.0, SV5.1, SV6.0
TSX3710001 <=08 SV3.0, SV3.5, SV4.0, SV5.0, SV5.1, SV6.0
TSX3721001 <=08 SV3.0, SV3.5, SV4.0, SV5.0, SV5.1, SV6.0
TSX3722001 <=08 SV3.0, SV3.5, SV4.0, SV5.0, SV5.1, SV6.0
TSX PREMIUM hardware bases
-----------------------------
Processor type PV Compatible operating systems versions
TSX P57102 <=08 SV3.0, SV3.4, SV3.5, SV3.6, SV3.7, SV3.8
TSX P57102 = 10 SV4.1, SV4.2, SV4.3
TSX P57103 = 01 SV5.0, SV5.1, SV5.2, SV5.3, SV5.4, SV5.5, SV5.6, SV5.7, SV5.8
TSX P57153 = 01 SV5.0, SV5.1, SV5.2, SV5.3, SV5.4, SV5.5, SV5.6, SV5.7, SV5.8
TSX P57202, TSX P57252 <=08 SV3.0, SV3.4, SV3.5, SV3.6, SV3.7, SV3.8
TSX P57202, TSX P57252 = 10 SV4.1, SV4.2, SV4.3
TSX P57203, TSX P57253 = 01 SV5.0, SV5.1, SV5.2, SV5.3, SV5.4, SV5.5, SV5.6, SV5.7, SV5.8
TSX P572623, TSX P572823 = 01 SV5.4, SV5.5, SV5.6, SV5.7, SV5.8
TSX P57302, TSX P57352 <=08 SV3.0, SV3.4, SV3.5, SV3.6, SV3.7, SV3.8
TSX P57302, TSX P57352 = 10 SV4.1, SV4.2, SV4.3
TSX P57303, TSX P57353 = 01 SV5.0, SV5.1, SV5.2, SV5.3, SV5.4, SV5.5, SV5.6, SV5.7, SV5.8
TSX P573623 = 01 SV5.4, SV5.5, SV5.6, SV5.7, SV5.8
TSX P57402, TSX P57452 <= 08 SV3.1, SV3.4, SV3.6, SV3.7, SV3.8
TSX P57402, TSX P57452 = 09 SV4.1, SV4.2, SV4.3
TSX P57453 = 01 SV5.0, SV5.1, SV5.2, SV5.3, SV5.4, SV5.5, SV5.6, SV5.7, SV5.8
TSX P574823 = 01 SV5.4, SV5.5, SV5.6, SV5.7, SV5.8
TPMX P57102 <= 09 SV3.0, SV3.4, SV3.5, SV3.6, SV3.7, SV3.8
TPMX P57102 = 11 SV4.1, SV4.2, SV4.3
TPMX P57202 <= 06 SV3.1, SV3.4, SV3.6, SV3.7, SV3.8
TPMX P57202 = 07 SV4.1, SV4.2, SV4.3
TPMX P57352 <= 07 SV3.1, SV3.4, SV3.6, SV3.7, SV3.8
TPMX P57352 = 08 SV4.1, SV4.2, SV4.3
TPMX P57452 <= 07 SV3.1, SV3.4, SV3.6, SV3.7, SV3.8
TPMX P57452 = 08 SV4.1, SV4.2, SV4.3
TPCX 571012 <= 08 SV3.0, SV3.4, SV3.5, SV3.6, SV3.7, SV3.8
TPCX 573512 <= 09 SV3.0, SV3.4, SV3.5, SV3.6, SV3.7, SV3.8
TPCX 57203 = 01 SV5.0, SV5.1, SV5.2, SV5.3, SV5.4, SV5.5, SV5.6, SV5.7, SV5.8
TPCX 57353 = 01 SV5.0, SV5.1, SV5.2, SV5.3, SV5.4, SV5.5, SV5.6, SV5.7, SV5.8
Examples of operating systems files:
For a TSX MICRO TSX3721001 PLC, the compatible operating systems versions are SV3.0, SV3.5, SV4.0, SV5.0, SV5.1, SV6.0.
We recommend that you use version SV6.0 contained in the TSX_372x_V60.bin file.
For a TSX PREMIUM TSX57352 PLC version PV7, the compatible operating systems are SV3.1, SV3.4, SV3.6, SV3.7, and SV3.8.
We recommend that you use version SV3.8 contained in the TSX_57352_V38.BIN file.
If this FAQ did not solve your issue, you can chat with us at chat with us or e-mail us at customer.services@se.com to create a case with our Technical Support Team.
If you are not located in North America, please contact your local Customer Care Center for assistance:
Released for: Schneider Electric USA
Explore more
Range:
Explore more
Range:
Need help?
Product Selector
Quickly and easily find the right products and accessories for your applications.
Get a Quote
Start your sales inquiry online and an expert will connect with you.
Where to buy?
Easily find the nearest Schneider Electric distributor in your location.
Help Center
Find support resources for all your needs, in one place.