What are the repair parts for the SC3042M200PS, series M01?
Issue:
Current Design Repair Parts
Product Line:
Combination Service Entrance Devices
Resolution:
NOTE: WIRING DIAGRAM AND LABELS ARE NOT INCLUDED ON THE PARTS LISTED BELOW.
The parts listed here are the only parts considered field repairable:
Meter Cover Assembly - 4056171950
Meter Cover Mounting Screw - 4020513002K (contains 10 screws; only 2 are required)
Utility Pullbox Cover - 4056194550 (includes cover latch)
Utility Pullbox Cover Sealing Screw - X1299
Load Center Cover Assembly - 4056172050 (includes latch and hinges)
Load Center Cover Mounting Screws - 2142217101 (2 required)
Dead Front Interior Trim - 4056170001 (labels not included)
Dead Front Interior Trim Mounting Screw - 4020513002K (contains 10 screws; only 2 are required)
Load Center Interior - MTR10002 (main breaker not included)
Load Center Interior Mounting Screw - 4020510001 (2 required)
Main Breaker - QOM2200VH (mounting screw included)
Main Breaker mounting keps nut - 2342702001 (2 required)
Meter Base - 7329882750 (phenolic base only)
Meter Base Mounting Screw - 2142717200 (2 required)
Meter Socket Jaw - 7329794850 (4 required for complete meter socket; blade guide not included)
Meter Jaw Mounting Keps Nut - 2342702001 (per meter jaw)
Meter Jaw Blade Guide - 4052761901 (per meter jaw)
Meter Jaw with Blade Guide - 7329746450 (4 required for complete meter socket; includes blue blade guide)
Meter Sealing Ring - 2920910001
Main Line Side Phase Lugs - 4025116051 (per phase)
Keps Nut for Main Line Side Phase Lugs - 2342702001 (per lug)
Load Center Cover Hasp - 4056174201
NOTE: WIRING DIAGRAM AND LABELS ARE NOT INCLUDED ON THE PARTS LISTED ABOVE
Current Design Repair Parts
Product Line:
Combination Service Entrance Devices
Resolution:
NOTE: WIRING DIAGRAM AND LABELS ARE NOT INCLUDED ON THE PARTS LISTED BELOW.
The parts listed here are the only parts considered field repairable:
Meter Cover Assembly - 4056171950
Meter Cover Mounting Screw - 4020513002K (contains 10 screws; only 2 are required)
Utility Pullbox Cover - 4056194550 (includes cover latch)
Utility Pullbox Cover Sealing Screw - X1299
Load Center Cover Assembly - 4056172050 (includes latch and hinges)
Load Center Cover Mounting Screws - 2142217101 (2 required)
Dead Front Interior Trim - 4056170001 (labels not included)
Dead Front Interior Trim Mounting Screw - 4020513002K (contains 10 screws; only 2 are required)
Load Center Interior - MTR10002 (main breaker not included)
Load Center Interior Mounting Screw - 4020510001 (2 required)
Main Breaker - QOM2200VH (mounting screw included)
Main Breaker mounting keps nut - 2342702001 (2 required)
Meter Base - 7329882750 (phenolic base only)
Meter Base Mounting Screw - 2142717200 (2 required)
Meter Socket Jaw - 7329794850 (4 required for complete meter socket; blade guide not included)
Meter Jaw Mounting Keps Nut - 2342702001 (per meter jaw)
Meter Jaw Blade Guide - 4052761901 (per meter jaw)
Meter Jaw with Blade Guide - 7329746450 (4 required for complete meter socket; includes blue blade guide)
Meter Sealing Ring - 2920910001
Main Line Side Phase Lugs - 4025116051 (per phase)
Keps Nut for Main Line Side Phase Lugs - 2342702001 (per lug)
Load Center Cover Hasp - 4056174201
NOTE: WIRING DIAGRAM AND LABELS ARE NOT INCLUDED ON THE PARTS LISTED ABOVE
Released for: Schneider Electric USA
Explore more
Product:
Explore more
Product:
Need help?
Product Selector
Quickly and easily find the right products and accessories for your applications.
Get a Quote
Start your sales inquiry online and an expert will connect with you.
Where to buy?
Easily find the nearest Schneider Electric distributor in your location.
Help Center
Find support resources for all your needs, in one place.