What are the repair parts for the SC3042M225PF, Series M01?

Issue:
Current Design Repair Parts

Product Line:
Combination Service Entrance Devices

Resolution:
NOTE: WIRING DIAGRAM AND LABELS ARE NOT INCLUDED ON THE PARTS LISTED BELOW.
The parts listed here are the only parts considered field repairable:
Meter Cover Assembly - 4053442852
Meter Cover Mounting Screw - 4020513001K (contains 10 screws; only one screw is required to secure the cover)
Branch Wiring Gutter Cover (Below Meter Cover) - 4056178101
Branch Wiring Gutter Cover Mounting Screw - 4020513001K (contains 10 screws; only one screw is required to secure the cover)
Utility Pullbox Cover - 4056181150 (includes cover latch)
Utility Pullbox Cover Sealing Screw - X1299
Load Center Cover Assembly - MTR10570 (includes hinges)
Load Center Cover Mounting Screws - 2142217101 (2 required)
Dead Front Interior Trim - EAV67728
Dead Front Interior Trim Mounting Screw - 4020513001K (contains 10 screws; only two screws are required to secure the interior trim)
Load Center Interior - MTR10002 (main breaker and large neutral lugs not included)
Load Center Interior Mounting Screw - 4020510001 (2 required)
Main Breaker - QOM2225VH
Main Breaker mounting keps nut - 2342702001 (2 required; attaches the load side of MB to studs in main bus bars)
Meter Base - 4054102503 (phenolic base only - does not include line and load phase jaws, see below. If 5th jaw is required order catalog number 5J)
Meter Base Mounting Screw - 2142717200
Meter Socket Jaw - 7329794850 (4 required for complete meter socket; blade guide not included)
Meter Jaw Mounting Keps Nut - 2342702001 (one PER meter jaw)
Meter Jaw Blade Guide - 4052761901 (one PER meter jaw)
Meter Jaw with Blade Guide - 7329746450 (4 required for complete meter socket and includes blade guide)
Meter Sealing Ring - 2920910001
Left Line Side Phase Lug - 4025116051
Left Line Side Phase Lugs Mounting Bolt - 2271020242
Left Line Side Phase Lugs Mounting Keps Nut - 2342702001
NOTES:
1) WIRING DIAGRAM AND LABELS ARE NOT INCLUDED ON THE PARTS LISTED ABOVE
2) The device comes standard with five large branch neutral lugs; two of part number LK70AN, one of part number 4025130250, one of part number LK100AN, and one of part number LK125AN; IF NEEDING REPLACEMENTS, ORDER SEPARATELY.

Schneider Electric USA

Explore more

Discuss this topic with experts

Visit our community and get advice from experts and peers on this topic and more

Explore more

Need help?

Product Selector

Quickly and easily find the right products and accessories for your applications.

Get a Quote

Start your sales inquiry online and an expert will connect with you.

Where to buy?

Easily find the nearest Schneider Electric distributor in your location.

Help Center

Find support resources for all your needs, in one place.