What Communication Options Are Available for Altivar Machine ATV320 Drives?

Resolution:
ATV320 drives include an integrated RJ45 communication port for Modbus serial and CANopen. Additional communication options depend on the ATV320 form factor:

ATV320 Book (ATV320-B)

  • Integrated RJ45 port for Modbus serial/CANopen
  • Dedicated slot for an optional communication module

ATV320 Compact (ATV320-C)

  • Integrated RJ45 port for Modbus serial/CANopen
  • Optional communication modules can be installed using the VW3A3600 mechanical adapter, ordered separately

The following optional communication modules are available:

  • Modbus TCP and EtherNet/IP: VW3A3616
  • PROFIBUS DP V1: VW3A3607
  • DeviceNet: VW3A3609
  • EtherCAT: VW3A3601
  • POWERLINK: VW3A3619
  • PROFINET: VW3A3627

If this article does not answer your question, check out our FAQ database that has answers to more commonly asked questions:

Frequently Asked Questions - Schneider Electric (se.com)

If this FAQ did not solve your issue, you can call us at 1-888-778-2733 Option 2 and then 4 or e-mail us atdrive.products.support@se.comto create a case with our Technical Support Team.

If you are not located in North America, please contact your local Customer Care Center for assistance:

Support | Schneider Electric Global (se.com)

Schneider Electric USA

Explore more

Discuss this topic with experts

Visit our community and get advice from experts and peers on this topic and more

Explore more

Need help?

Product Selector

Quickly and easily find the right products and accessories for your applications.

Get a Quote

Start your sales inquiry online and an expert will connect with you.

Where to buy?

Easily find the nearest Schneider Electric distributor in your location.

Help Center

Find support resources for all your needs, in one place.