How can we help you today?

Looking to replace the LXM23DU04M3X and BCH0602O12A1C

Issue:
Looking to replace the LXM23DU04M3X and BCH0602O12A1C servo motor

Product Line:
LXM23

Resolution:

The direct replacement is:
LXM28AU04M3X and BCH2LD0431CA5C combination:
- Supply voltage single phase 200/240 VAC or 3 phase 200/240 VAC, 50/ 60 Hz
- Nominal torque 1.27 Nm
- Maximum peak torque 3.81 Nm
- Nominal speed 3000 RPM
- 0.4 Kw motor rating
- 0.27 kgcm2 motor inertia without holding brake
You cannot copy the parameters from the old drive to the new drive. They will have to be entered manually in the new LXM28 drive.

Schneider Electric USA

Explore more
Range:
Users group

Discuss this topic with experts

Visit our community and get advice from experts and peers on this topic and more
Explore more
Range:
  • Help Center
  • Contact Sales
  • Find our Offices
  • Where to Buy
  • Tech Support: 877-342-5173
  • Careers
  • Company Profile
  • Investors
  • Newsroom
  • Report a Misconduct
  • Product Documentation
  • Software and Firmware
  • Product Selector
  • Product Replacement
  • DigestPLUS Online Catalog
  • Industries
  • Partners
  • Schneider Electric Community
  • Events
  • Privacy Policy
  • Cookie Notice
  • Terms of use
  • Change your cookie settings