Data Center Expert | What are the default credentials?
Issue:
Default credentials for StruxureWare Data Center Expert
Product Line
StruxureWare Data Center Expert (DCE)
InfraStruXure Central (ISXC)
Environment:
StruxureWare Data Center Expert (all versions)
Resolution:
Web Interface & Desktop Client
Username: apc
Password: apc
Viewing Network Settings
Username: apcinfo
Password: [user defined]
NOTE: Upon first setup using the apcsetup login, the password will be changed to a user defined password.
Configuring Network Settings
Username: apcsetup
Password: apcsetup (Upon first logging in the password will be required to be changed)
Instructions can be found in knowledge base FA234266.
Root Operating System
Username: N/A
Password: N/A
For details see knowledge base FA222410.
NOTE: Please keep a secure record of this for future use.
If prompted, here are the initial configuration passwords.
Username: apcsetup
Password: apcsetup
Username: apcinfo
Password: apcinfo
Username: apcreset
Password: (7.9.2)= apc | (7.9.3 and above)= apcreset
Default credentials for StruxureWare Data Center Expert
Product Line
StruxureWare Data Center Expert (DCE)
- Basic Appliance (AP9465)
- Standard Appliance (AP9470)
- Enterprise Appliance (AP9475)
- Virtual Appliance (AP94VMACT)
StruxureWare Central (SWC)- Standard Appliance (AP9470)
- Enterprise Appliance (AP9475)
- Virtual Appliance (AP94VMACT)
InfraStruXure Central (ISXC)
Environment:
StruxureWare Data Center Expert (all versions)
Resolution:
Web Interface & Desktop Client
Username: apc
Password: apc
Viewing Network Settings
Username: apcinfo
Password: [user defined]
NOTE: Upon first setup using the apcsetup login, the password will be changed to a user defined password.
Configuring Network Settings
Username: apcsetup
Password: apcsetup (Upon first logging in the password will be required to be changed)
Instructions can be found in knowledge base FA234266.
Root Operating System
Username: N/A
Password: N/A
For details see knowledge base FA222410.
NOTE: Please keep a secure record of this for future use.
If prompted, here are the initial configuration passwords.
Username: apcsetup
Password: apcsetup
Username: apcinfo
Password: apcinfo
Username: apcreset
Password: (7.9.2)= apc | (7.9.3 and above)= apcreset
Released for: Schneider Electric USA
Explore more
Range:
Explore more
Range:
Need help?
Product Selector
Quickly and easily find the right products and accessories for your applications.
Get a Quote
Start your sales inquiry online and an expert will connect with you.
Where to buy?
Easily find the nearest Schneider Electric distributor in your location.
Help Center
Find support resources for all your needs, in one place.