How can we help you today?
How do you set the backlight timeout in the VW3A1111 keypad of AltivarProcess ATV900, ATV600?
Issue:
How do you set the backlight timeout in the VW3A1111 keypad?
Product Line:
Altivar Process Drives using the VW3A1111 keypad
Environment:
All
Cause:
Preference
Resolution:
There is parameter for standby timeout in VW3A1111 with default value 60s. It is possible to set it to 'NO'. This parameter is stored in the remote keypad (not in drive). How to change it depends on the drive being used.
ATV32/ATV320:
Main menu -> interface -> Display config. -> LCD Settings -> Stand-by delay
Note: access level has to be set to expert
ATV630/ATV930/ATV340:
Main menu -> My preferences -> LCD settings ->Stand by
ATV61/ATV71
Main menu -> Display config. -> LCD Settings -> Stand-by delay
Note: access level has to be set to expert
How do you set the backlight timeout in the VW3A1111 keypad?
Product Line:
Altivar Process Drives using the VW3A1111 keypad
Environment:
All
Cause:
Preference
Resolution:
There is parameter for standby timeout in VW3A1111 with default value 60s. It is possible to set it to 'NO'. This parameter is stored in the remote keypad (not in drive). How to change it depends on the drive being used.
ATV32/ATV320:
Main menu -> interface -> Display config. -> LCD Settings -> Stand-by delay
Note: access level has to be set to expert
ATV630/ATV930/ATV340:
Main menu -> My preferences -> LCD settings ->Stand by
ATV61/ATV71
Main menu -> Display config. -> LCD Settings -> Stand-by delay
Note: access level has to be set to expert
Released for: Schneider Electric USA
Explore more
Range:
Explore more
Range:
Need help?
Product Selector
Quickly and easily find the right products and accessories for your applications.
Get a Quote
Start your sales inquiry online and an expert will connect with you.
Where to buy?
Easily find the nearest Schneider Electric distributor in your location.
Help Center
Find support resources for all your needs, in one place.