How do I break down an ATV660 part number to determine size, voltage, options, etc?

Issue:
ATV660 part number break down

Product Line:
Altivar 660 enclosed drives

Environment:
All

Cause:
Need to break down a part number

Resolution:
This information is located in the ATV660 Instruction Manual, which can be found here.

The options tables start in Section 2- Product Characteristics. Use the tables to go through the part number by each option.
The bulletin is also attached to this article.

Catalog Number Example: ATV660D22T4N2ANWAANAGK

Field
01–0203–04567891011121314
ATV660D22T4N2ANWAANA, G, K
Altivar 660 Process Drive3 hp460 V, 3 phaseNormal Duty Power RatingUL ListedUL Type 12K EnclosureNo Harmonic MitigationWithout BypassH-O-A Speed Pot.Red Power On, Yellow Tripped, Green AFC Run, Yellow AutoNo Comm. CardEthernet Port in Front Door; Type 1 SPD; Additional 150 VA Control Power

Field

Digit

Characteristic

Description

01–02

1–6

Drive Style

Altivar 660 Process Drive, 2-quadrant, 6-pulse drive

03–04

7–9

Power Rating (kW)

Normal Duty
U07 = 1 hp
U15 = 2 hp
U22 = 3 hp
U40 = 5 hp
U55 = 7.5 hp
U75 = 10 hp
D11 = 15 hp
D15 = 20 hp
D18 = 25 hp
D22 = 30 hp
D30 = 40 hp
D37 = 50 hp
D45 = 60 hp
D55 = 75 hp
D75 = 100 hp
D90 = 125 hp
C11 = 150 hp
C13 = 200 hp
C16 = 250 hp
C20 = 300 hp
C25 = 400 hp
C31 = 500 hp
C40 = 600 hp
C50 = 700 hp
C63 = 900 hp
Heavy Duty
U15 = 1 hp
U22 = 2 hp
U30 = 3 hp
U55 = 5 hp
U75 = 7.5 hp
D11 = 10 hp
D15 = 15 hp
D18 = 20 hp
D22 = 25 hp
D30 = 30 hp
D37 = 40 hp
D45 = 50 hp
D55 = 60 hp
D75 = 75 hp
D90 = 100 hp
C11 = 125 hp
C13 = 150 hp
C16 = 200 hp
C20 = 250 hp
C25 = 300 hp
C31 = 400 hp
C40 = 500 hp
C50 = 600 hp
C63 = 700 hp

05

10–11

Voltage Class

P3 = 208 V, Three Phase
U3 = 230 V, Three Phase
T4 = 460 V, Three Phase

06

12

Duty Rating

N = Normal Duty
H = Heavy Duty

07

13

Region

2 = UL Marking
6 = cUL Marking (Canada)

08

14

Enclosure Type

G = Type 1 General Purpose
A = Type 12K Industrial Use, Dust-tight/Drip-tight
H = Type 3R Outdoor Use

09

15

Line Harmonic Mitigation

N = None
A = Line Reactor
M = Passive Harmonic Filter

10

16

Power Circuit

S = Integral Softstart Bypass
W = Without Bypass
Y = Integral Full-Voltage Bypass

11

17

Control Options

N = Prewired for Remote H-O-A
A = H-O-A, Speed Potentiometer
B = H-O-A, Speed Potentiometer, Start/Stop Push Button

12

18

Light Options

N = None
A = Red Power On, Yellow Tripped, Green AFC Run, Yellow Auto
B = Red Power On, Yellow Tripped, Green AFC Run (Default)

13

19

Communication Card

N = None
A = Profibus DP V1
B = CANopen Daisy Chain
C = DeviceNet
D = CANopen SUB-D
E = CANopen Open Style
F = ProfiNet
G = Ethernet IP Dual Port
H = EtherCat
J = Bacnet MS/TP
K = Ethernet IP, Modbus, TCP, Multidrive link

14

Varies

Miscellaneous Options

A = Ethernet Port in Front Door
B = Line Contactor
C = Drive I/O Extension
D = Relay Output Card
E = 0–10 V Auto Speed Reference
F = 1 N.O. (Form A) Auxiliary Auto Mode Contact
G = Surge Protective Device (SPD) (Type 1)
H = SPD (Type 2)
K = Additional 150 VA Control Power
L = Push-to-Test Pilot Lights
P = Permanent Wire Markers
Q = Door-Mounted Overload Reset Push Button
R = Service Entrance (3R only)
S = 50°C Ambient Operation
T = Service Switch
U = Wireway Cubical (when available)
X = dV/dt Filter (1000 ft)
Y = Seismic Certification

Field

Digit

Characteristic

Description

01–02

1–6

Drive Style

Altivar 660 Process Drive, 2-quadrant, 6-pulse drive

03–04

7–9

Power Rating (kW)

Normal Duty
U07 = 1 hp
U15 = 2 hp
U22 = 3 hp
U40 = 5 hp
U55 = 7.5 hp
U75 = 10 hp
D11 = 15 hp
D15 = 20 hp
D18 = 25 hp
D22 = 30 hp
D30 = 40 hp
D37 = 50 hp
D45 = 60 hp
D55 = 75 hp
D75 = 100 hp
D90 = 125 hp
C11 = 150 hp
C13 = 200 hp
C16 = 250 hp
C20 = 300 hp
C25 = 400 hp
C31 = 500 hp
C40 = 600 hp
C50 = 700 hp
C63 = 900 hp
Heavy Duty
U15 = 1 hp
U22 = 2 hp
U30 = 3 hp
U55 = 5 hp
U75 = 7.5 hp
D11 = 10 hp
D15 = 15 hp
D18 = 20 hp
D22 = 25 hp
D30 = 30 hp
D37 = 40 hp
D45 = 50 hp
D55 = 60 hp
D75 = 75 hp
D90 = 100 hp
C11 = 125 hp
C13 = 150 hp
C16 = 200 hp
C20 = 250 hp
C25 = 300 hp
C31 = 400 hp
C40 = 500 hp
C50 = 600 hp
C63 = 700 hp

05

10–11

Voltage Class

P3 = 208 V, Three Phase
U3 = 230 V, Three Phase
T4 = 460 V, Three Phase

06

12

Duty Rating

N = Normal Duty
H = Heavy Duty

07

13

Region

2 = UL Marking
6 = cUL Marking (Canada)

08

14

Enclosure Type

G = Type 1 General Purpose
A = Type 12K Industrial Use, Dust-tight/Drip-tight
H = Type 3R Outdoor Use

09

15

Line Harmonic Mitigation

N = None
A = Line Reactor
M = Passive Harmonic Filter

10

16

Power Circuit

S = Integral Softstart Bypass
W = Without Bypass
Y = Integral Full-Voltage Bypass

11

17

Control Options

N = Prewired for Remote H-O-A
A = H-O-A, Speed Potentiometer
B = H-O-A, Speed Potentiometer, Start/Stop Push Button

12

18

Light Options

N = None
A = Red Power On, Yellow Tripped, Green AFC Run, Yellow Auto
B = Red Power On, Yellow Tripped, Green AFC Run (Default)

13

19

Communication Card

N = None
A = Profibus DP V1
B = CANopen Daisy Chain
C = DeviceNet
D = CANopen SUB-D
E = CANopen Open Style
F = ProfiNet
G = Ethernet IP Dual Port
H = EtherCat
J = Bacnet MS/TP
K = Ethernet IP, Modbus, TCP, Multidrive link

14

Varies

Miscellaneous Options

A = Ethernet Port in Front Door
B = Line Contactor
C = Drive I/O Extension
D = Relay Output Card
E = 0–10 V Auto Speed Reference
F = 1 N.O. (Form A) Auxiliary Auto Mode Contact
G = Surge Protective Device (SPD) (Type 1)
H = SPD (Type 2)
K = Additional 150 VA Control Power
L = Push-to-Test Pilot Lights
P = Permanent Wire Markers
Q = Door-Mounted Overload Reset Push Button
R = Service Entrance (3R only)
S = 50°C Ambient Operation
T = Service Switch
U = Wireway Cubical (when available)
X = dV/dt Filter (1000 ft)
Y = Seismic Certification

Schneider Electric USA

Attachment(s)

Explore more

Discuss this topic with experts

Visit our community and get advice from experts and peers on this topic and more

Explore more

Need help?

Product Selector

Quickly and easily find the right products and accessories for your applications.

Get a Quote

Start your sales inquiry online and an expert will connect with you.

Where to buy?

Easily find the nearest Schneider Electric distributor in your location.

Help Center

Find support resources for all your needs, in one place.