How can we help you today?
What can I do if the tag is not detected properly in Ecostruxure Augmented Operator Advisor?
Follow these rules when using tags:
- Place the tag on a solid flat surface or on a window.
- Do not use a tag in an environment with a grill or a mesh: the detection can be very slow or impossible, as the software will have difficulty differentiating between the tag and the grill/mesh.
- Reference photos must be taken directly in front of the tag. The photo plane must be parallel to the tag plane for best results.
- The detection camera plane must be also parallel to the tag plane. If a tag is placed at the top of a scene, consider tilting the tag downward to respect this parallelism. Any deviation from parallel of this photo will reduce the probability of tag detection.
- When identifying the tag placement in the images, use the four corners of the tag itself, as indicated in green here:
Released for: Schneider Electric USA
Explore more
Range:
Explore more
Range:
Need help?
Product Selector
Quickly and easily find the right products and accessories for your applications.
Get a Quote
Start your sales inquiry online and an expert will connect with you.
Where to buy?
Easily find the nearest Schneider Electric distributor in your location.
Help Center
Find support resources for all your needs, in one place.