Replacement Components for Surgelogic™ QED-2 Switchboard IMA Surge Protective Devices

Article available in these languages: Spanish

Issue:
What are the replacement components for QED-2 Switchboard IMA series Surge Protective Devices?

Product Line:
Surge Protective Devices (SPDs)

Environment:
QED-2 Switchboard Type IMA surge protective devices.

Cause:
Replacement or Repair Parts

Resolution:
To determine the correct Replacement parts to purchase for your QED-2 Switchboard Type IMA series Surge Protective Devices (SPDs), see the Replacement Component Selector Table below. An example of a typical product label and catalog number is at the end of this article.

Replacement Component Matrix
Catalog NumberPeak Surge CurrentModule Catalog Number
"A" Phase
Module Catalog Number
"B" Phase
Module Catalog Number
"C" Phase
Diagnostic Cable
(3 per kit)
Front Display
(NEMA 1 SPDs only)
TVS1IMA12B2120kAMA1IMA12N/AMA1IMA12TVS60PCKTVS1DSPHC
TVS1IMA16B2160kAMA1IMA16N/AMA1IMA16TVS60PCKTVS1DSPHC
TVS1IMA24B2240kAMA1IMA24N/AMA1IMA24TVS60PCKTVS1DSPHC
TVS1IMA32B2320kAMA1IMA16 (2 Modules Required)N/AMA1IMA16 (2 Modules Required)TVS60PCK (2 Kits Required)TVS6DSPHC
TVS1IMA48B2480kAMA1IMA24 (2 Modules Required)N/AMA1IMA24 (2 Modules Required)TVS60PCK (2 Kits Required)TVS6DSPHC
TVS2IMA12B2120kAMA1IMA12MA1IMA12MA1IMA12TVS60PCKTVS3DSPHC
TVS2IMA16B2160kAMA1IMA16MA1IMA16MA1IMA16TVS60PCKTVS3DSPHC
TVS2IMA24B2240kAMA1IMA24MA1IMA24MA1IMA24TVS60PCKTVS3DSPHC
TVS2IMA32B2320kAMA1IMA16 (2 Modules Required)MA1IMA16 (2 Modules Required)MA1IMA16 (2 Modules Required)TVS60PCK (2 Kits Required)TVS6DSPHC
TVS2IMA48B2480kAMA1IMA24 (2 Modules Required)MA1IMA24 (2 Modules Required)MA1IMA24 (2 Modules Required)TVS60PCK (2 Kits Required)TVS6DSPHC
TVS3IMA12B2120kAMA1IMA12MA3IMA12MA1IMA12TVS60PCKTVS3DSPHC
TVS3IMA16B2160kAMA1IMA16MA3IMA16MA1IMA16TVS60PCKTVS3DSPHC
TVS3IMA24B2240kAMA1IMA24MA3IMA24MA1IMA24TVS60PCKTVS3DSPHC
TVS3IMA32B2320kAMA1IMA16 (2 Modules Required)MA3IMA16 (2 Modules Required)MA1IMA16 (2 Modules Required)TVS60PCK (2 Kits Required)TVS6DSPHC
TVS3IMA48B2480kAMA1IMA24 (2 Modules Required)MA3IMA24 (2 Modules Required)MA1IMA24 (2 Modules Required)TVS60PCK (2 Kits Required)TVS6DSPHC
TVS4IMA12B2120kAMA4IMA12MA4IMA12MA4IMA12TVS60PCKTVS3DSPHC
TVS4IMA16B2160kAMA4IMA16MA4IMA16MA4IMA16TVS60PCKTVS3DSPHC
TVS4IMA24B2240kAMA4IMA24MA4IMA24MA4IMA24TVS60PCKTVS3DSPHC
TVS4IMA32B2320kAMA4IMA16 (2 Modules Required)MA4IMA16 (2 Modules Required)MA4IMA16 (2 Modules Required)TVS60PCK (2 Kits Required)TVS6DSPHC
TVS4IMA48B2480kAMA4IMA24 (2 Modules Required)MA4IMA24 (2 Modules Required)MA4IMA24 (2 Modules Required)TVS60PCK (2 Kits Required)TVS6DSPHC


Surgelogic Label

To find your SPD part #, locate a white Surgelogic sticker on the interior of your SPD. This can typically be found on the sidewalls or on the door of the SPD. The label will look like the following:

tvss

Schneider Electric USA

Explore more
Range:
Users group

Discuss this topic with experts

Visit our community and get advice from experts and peers on this topic and more
Explore more
Range:
  • Products Documentation
  • Software Downloads
  • Product Selector
  • Product Substitution and Replacement
  • Help and Contact Center
  • Where to buy
  • Get a Quote
  • Find our Offices
  • Schneider Electric Community
  • Careers
  • Company Profile
  • Report a misconduct
  • Accessibility
  • Newsroom
  • Investors
  • EcoStruxure
  • Job Search
  • Blog
  • Tech Support: 877-342-5173
  • Privacy Policy
  • Cookie Notice
  • Terms of use
  • Change your cookie settings