Our Brands

Impact-Company-Logo-English Black-01-177x54

Schneider Electric USA Website

Welcome to our website.
		
How can we help you today?
Replacement Components for Surgelogic™ 240V Delta 3 Ø, 3-Wire+G Legacy EMA Series Surge Protective Devices
Issue:
What are the replacement components for 240V DELTA 3-Phase, 3-wire+Ground Legacy EMA Series Surge Protective Devices?

Product Line:
Surge Protective Devices (SPDs)

Environment:
240V Delta 3 Ø, 3-Wire+G Legacy EMA surge protective devices.

Cause:
Replacement or Repair Parts

Resolution:
To determine the correct Replacement parts to purchase for your 240V Delta 3 Ø, 3-Wire+G Legacy EMA Series Surge Protective Devices (SPDs), see the Replacement Component Selector Table below. An example of a typical product label and catalog number is at the end of this article.

Replacement Component Matrix
Catalog NumberPeak Surge CurrentModule Catalog Number
"A" Phase
Module Catalog Number
"B" Phase
Module Catalog Number
"C" Phase
Diagnostic Cable
(3 per kit)
Front Display
(NEMA 1 SPDs only)
TVS6EMA10A100kAMA6IMA10MA6IMA10MA6IMA10TVS36PCKTVS3DSPHC
TVS6EMA10ASWT100kAMA6IMA10MA6IMA10MA6IMA10TVS36PCKTVS3DSPHC
TVS6EMA10A1100kAMA6IMA101MA6IMA101MA6IMA101TVS36PCKTVS3DSPHC
TVS6EMA10AI100kAMA6IMA10MA6IMA10MA6IMA10TVS36PCKTVS3DSPHC
TVS6EMA10AISWT100kAMA6IMA10MA6IMA10MA6IMA10TVS36PCKTVS3DSPHC
TVS6EMA10AISWT1100kAMA6IMA101MA6IMA101MA6IMA101TVS36PCKTVS3DSPHC
TVS6EMA10AI1100kAMA6IMA101MA6IMA101MA6IMA101TVS36PCKTVS3DSPHC
TVS6EMA10S100kAMA6IMA10MA6IMA10MA6IMA10TVS36PCKTVS3DSPHC
TVS6EMA10SI100kAMA6IMA10MA6IMA10MA6IMA10TVS36PCKTVS3DSPHC
TVS6EMA10SSWT100kAMA6IMA10MA6IMA10MA6IMA10TVS36PCKTVS3DSPHC
TVS6EMA10ASWT1100kAMA6IMA101MA6IMA101MA6IMA101TVS36PCKTVS3DSPHC
TVS6EMA10SISWT100kAMA6IMA10MA6IMA10MA6IMA10TVS36PCKTVS3DSPHC
TVS6EMA10S1100kAMA6IMA101MA6IMA101MA6IMA101TVS36PCKTVS3DSPHC
TVS6EMA10SSWT1100kAMA6IMA101MA6IMA101MA6IMA101TVS36PCKTVS3DSPHC
TVS6EMA10SI1100kAMA6IMA101MA6IMA101MA6IMA101TVS36PCKTVS3DSPHC
TVS6EMA10SISWT1100kAMA6IMA101MA6IMA101MA6IMA101TVS36PCKTVS3DSPHC
Catalog NumberPeak Surge CurrentModule Catalog Number
"A" Phase
Module Catalog Number
"B" Phase
Module Catalog Number
"C" Phase
Diagnostic Cable
(3 per kit)
Front Display
(NEMA 1 SPDs only)
TVS6EMA12A120kAMA6IMA12MA6IMA12MA6IMA12TVS36PCKTVS3DSPHC
TVS6EMA12ASWT120kAMA6IMA12MA6IMA12MA6IMA12TVS36PCKTVS3DSPHC
TVS6EMA12A1120kAMA6IMA121MA6IMA121MA6IMA121TVS36PCKTVS3DSPHC
TVS6EMA12AI120kAMA6IMA12MA6IMA12MA6IMA12TVS36PCKTVS3DSPHC
TVS6EMA12AISWT120kAMA6IMA12MA6IMA12MA6IMA12TVS36PCKTVS3DSPHC
TVS6EMA12AISWT1120kAMA6IMA121MA6IMA121MA6IMA121TVS36PCKTVS3DSPHC
TVS6EMA12AI1120kAMA6IMA121MA6IMA121MA6IMA121TVS36PCKTVS3DSPHC
TVS6EMA12S120kAMA6IMA12MA6IMA12MA6IMA12TVS36PCKTVS3DSPHC
TVS6EMA12SI120kAMA6IMA12MA6IMA12MA6IMA12TVS36PCKTVS3DSPHC
TVS6EMA12SSWT120kAMA6IMA12MA6IMA12MA6IMA12TVS36PCKTVS3DSPHC
TVS6EMA12ASWT1120kAMA6IMA121MA6IMA121MA6IMA121TVS36PCKTVS3DSPHC
TVS6EMA12SISWT120kAMA6IMA12MA6IMA12MA6IMA12TVS36PCKTVS3DSPHC
TVS6EMA12S1120kAMA6IMA121MA6IMA121MA6IMA121TVS36PCKTVS3DSPHC
TVS6EMA12SSWT1120kAMA6IMA121MA6IMA121MA6IMA121TVS36PCKTVS3DSPHC
TVS6EMA12SI1120kAMA6IMA121MA6IMA121MA6IMA121TVS36PCKTVS3DSPHC
TVS6EMA12SISWT1120kAMA6IMA121MA6IMA121MA6IMA121TVS36PCKTVS3DSPHC
Catalog NumberPeak Surge CurrentModule Catalog Number
"A" Phase
Module Catalog Number
"B" Phase
Module Catalog Number
"C" Phase
Diagnostic Cable
(3 per kit)
Front Display
(NEMA 1 SPDs only)
TVS6EMA16A160kAMA6IMA16MA6IMA16MA6IMA16TVS36PCKTVS3DSPHC
TVS6EMA16ASWT160kAMA6IMA16MA6IMA16MA6IMA16TVS36PCKTVS3DSPHC
TVS6EMA16A1160kAMA6IMA161MA6IMA161MA6IMA161TVS36PCKTVS3DSPHC
TVS6EMA16AI160kAMA6IMA16MA6IMA16MA6IMA16TVS36PCKTVS3DSPHC
TVS6EMA16AISWT160kAMA6IMA16MA6IMA16MA6IMA16TVS36PCKTVS3DSPHC
TVS6EMA16AISWT1160kAMA6IMA161MA6IMA161MA6IMA161TVS36PCKTVS3DSPHC
TVS6EMA16AI1160kAMA6IMA161MA6IMA161MA6IMA161TVS36PCKTVS3DSPHC
TVS6EMA16S160kAMA6IMA16MA6IMA16MA6IMA16TVS36PCKTVS3DSPHC
TVS6EMA16SI160kAMA6IMA16MA6IMA16MA6IMA16TVS36PCKTVS3DSPHC
TVS6EMA16SSWT160kAMA6IMA16MA6IMA16MA6IMA16TVS36PCKTVS3DSPHC
TVS6EMA16ASWT1160kAMA6IMA161MA6IMA161MA6IMA161TVS36PCKTVS3DSPHC
TVS6EMA16SISWT160kAMA6IMA16MA6IMA16MA6IMA16TVS36PCKTVS3DSPHC
TVS6EMA16S1160kAMA6IMA161MA6IMA161MA6IMA161TVS36PCKTVS3DSPHC
TVS6EMA16SSWT1160kAMA6IMA161MA6IMA161MA6IMA161TVS36PCKTVS3DSPHC
TVS6EMA16SI1160kAMA6IMA161MA6IMA161MA6IMA161TVS36PCKTVS3DSPHC
TVS6EMA16SISWT1160kAMA6IMA161MA6IMA161MA6IMA161TVS36PCKTVS3DSPHC
Catalog NumberPeak Surge CurrentModule Catalog Number
"A" Phase
Module Catalog Number
"B" Phase
Module Catalog Number
"C" Phase
Diagnostic Cable
(3 per kit)
Front Display
(NEMA 1 SPDs only)
TVS6EMA20A200kAMA6IMA20MA6IMA20MA6IMA20TVS36PCKTVS3DSPHC
TVS6EMA20ASWT200kAMA6IMA20MA6IMA20MA6IMA20TVS36PCKTVS3DSPHC
TVS6EMA20A1200kAMAIMA201MAIMA201MAIMA201TVS36PCKTVS3DSPHC
TVS6EMA20AI200kAMA6IMA20MA6IMA20MA6IMA20TVS36PCKTVS3DSPHC
TVS6EMA20AISWT200kAMA6IMA20MA6IMA20MA6IMA20TVS36PCKTVS3DSPHC
TVS6EMA20AISWT1200kAMAIMA201MAIMA201MAIMA201TVS36PCKTVS3DSPHC
TVS6EMA20AI1200kAMAIMA201MAIMA201MAIMA201TVS36PCKTVS3DSPHC
TVS6EMA20S200kAMA6IMA20MA6IMA20MA6IMA20TVS36PCKTVS3DSPHC
TVS6EMA20SI200kAMA6IMA20MA6IMA20MA6IMA20TVS36PCKTVS3DSPHC
TVS6EMA20SSWT200kAMA6IMA20MA6IMA20MA6IMA20TVS36PCKTVS3DSPHC
TVS6EMA20ASWT1200kAMAIMA201MAIMA201MAIMA201TVS36PCKTVS3DSPHC
TVS6EMA20SISWT200kAMA6IMA20MA6IMA20MA6IMA20TVS36PCKTVS3DSPHC
TVS6EMA20S1200kAMAIMA201MAIMA201MAIMA201TVS36PCKTVS3DSPHC
TVS6EMA20SSWT1200kAMAIMA201MAIMA201MAIMA201TVS36PCKTVS3DSPHC
TVS6EMA20SI1200kAMAIMA201MAIMA201MAIMA201TVS36PCKTVS3DSPHC
TVS6EMA20SISWT1200kAMAIMA201MAIMA201MAIMA201TVS36PCKTVS3DSPHC
Catalog NumberPeak Surge CurrentModule Catalog Number
"A" Phase
Module Catalog Number
"B" Phase
Module Catalog Number
"C" Phase
Diagnostic Cable
(3 per kit)
Front Display
(NEMA 1 SPDs only)
TVS6EMA24A240kAMA6IMA24MA6IMA24MA6IMA24TVS36PCKTVS3DSPHC
TVS6EMA24ASWT240kAMA6IMA24MA6IMA24MA6IMA24TVS36PCKTVS3DSPHC
TVS6EMA24A1240kAMA6IMA241MA6IMA241MA6IMA241TVS36PCKTVS3DSPHC
TVS6EMA24AI240kAMA6IMA24MA6IMA24MA6IMA24TVS36PCKTVS3DSPHC
TVS6EMA24AISWT240kAMA6IMA24MA6IMA24MA6IMA24TVS36PCKTVS3DSPHC
TVS6EMA24AISWT1240kAMA6IMA241MA6IMA241MA6IMA241TVS36PCKTVS3DSPHC
TVS6EMA24AI1240kAMA6IMA241MA6IMA241MA6IMA241TVS36PCKTVS3DSPHC
TVS6EMA24S240kAMA6IMA24MA6IMA24MA6IMA24TVS36PCKTVS3DSPHC
TVS6EMA24SI240kAMA6IMA24MA6IMA24MA6IMA24TVS36PCKTVS3DSPHC
TVS6EMA24SSWT240kAMA6IMA24MA6IMA24MA6IMA24TVS36PCKTVS3DSPHC
TVS6EMA24ASWT1240kAMA6IMA241MA6IMA241MA6IMA241TVS36PCKTVS3DSPHC
TVS6EMA24SISWT240kAMA6IMA24MA6IMA24MA6IMA24TVS36PCKTVS3DSPHC
TVS6EMA24S1240kAMA6IMA241MA6IMA241MA6IMA241TVS36PCKTVS3DSPHC
TVS6EMA24SSWT1240kAMA6IMA241MA6IMA241MA6IMA241TVS36PCKTVS3DSPHC
TVS6EMA24SI1240kAMA6IMA241MA6IMA241MA6IMA241TVS36PCKTVS3DSPHC
TVS6EMA24SISWT1240kAMA6IMA241MA6IMA241MA6IMA241TVS36PCKTVS3DSPHC
Catalog NumberPeak Surge CurrentModule Catalog Number
"A" Phase
Module Catalog Number
"B" Phase
Module Catalog Number
"C" Phase
Diagnostic Cable
(3 per kit)
Front Display
(NEMA 1 SPDs only)
TVS6EMA32A320kAMA6IMA16 (2 Modules Required)MA6IMA16 (2 Modules Required)MA6IMA16 (2 Modules Required)TVS36PCK (2 Kits Required)TVS6DSPHC
TVS6EMA32ASWT320kAMA6IMA16 (2 Modules Required)MA6IMA16 (2 Modules Required)MA6IMA16 (2 Modules Required)TVS36PCK (2 Kits Required)TVS6DSPHC
TVS6EMA32A1320kAMA6IMA161 (2 Modules Required)MA6IMA161 (2 Modules Required)MA6IMA161 (2 Modules Required)TVS36PCK (2 Kits Required)TVS6DSPHC
TVS6EMA32AI320kAMA6IMA16 (2 Modules Required)MA6IMA16 (2 Modules Required)MA6IMA16 (2 Modules Required)TVS36PCK (2 Kits Required)TVS6DSPHC
TVS6EMA32AISWT320kAMA6IMA16 (2 Modules Required)MA6IMA16 (2 Modules Required)MA6IMA16 (2 Modules Required)TVS36PCK (2 Kits Required)TVS6DSPHC
TVS6EMA32AISWT1320kAMA6IMA161 (2 Modules Required)MA6IMA161 (2 Modules Required)MA6IMA161 (2 Modules Required)TVS36PCK (2 Kits Required)TVS6DSPHC
TVS6EMA32AI1320kAMA6IMA161 (2 Modules Required)MA6IMA161 (2 Modules Required)MA6IMA161 (2 Modules Required)TVS36PCK (2 Kits Required)TVS6DSPHC
TVS6EMA32S320kAMA6IMA16 (2 Modules Required)MA6IMA16 (2 Modules Required)MA6IMA16 (2 Modules Required)TVS36PCK (2 Kits Required)TVS6DSPHC
TVS6EMA32SI320kAMA6IMA16 (2 Modules Required)MA6IMA16 (2 Modules Required)MA6IMA16 (2 Modules Required)TVS36PCK (2 Kits Required)TVS6DSPHC
TVS6EMA32SSWT320kAMA6IMA16 (2 Modules Required)MA6IMA16 (2 Modules Required)MA6IMA16 (2 Modules Required)TVS36PCK (2 Kits Required)TVS6DSPHC
TVS6EMA32ASWT1320kAMA6IMA161 (2 Modules Required)MA6IMA161 (2 Modules Required)MA6IMA161 (2 Modules Required)TVS36PCK (2 Kits Required)TVS6DSPHC
TVS6EMA32SISWT320kAMA6IMA16 (2 Modules Required)MA6IMA16 (2 Modules Required)MA6IMA16 (2 Modules Required)TVS36PCK (2 Kits Required)TVS6DSPHC
TVS6EMA32S1320kAMA6IMA161 (2 Modules Required)MA6IMA161 (2 Modules Required)MA6IMA161 (2 Modules Required)TVS36PCK (2 Kits Required)TVS6DSPHC
TVS6EMA32SSWT1320kAMA6IMA161 (2 Modules Required)MA6IMA161 (2 Modules Required)MA6IMA161 (2 Modules Required)TVS36PCK (2 Kits Required)TVS6DSPHC
TVS6EMA32SI1320kAMA6IMA161 (2 Modules Required)MA6IMA161 (2 Modules Required)MA6IMA161 (2 Modules Required)TVS36PCK (2 Kits Required)TVS6DSPHC
TVS6EMA32SISWT1320kAMA6IMA161 (2 Modules Required)MA6IMA161 (2 Modules Required)MA6IMA161 (2 Modules Required)TVS36PCK (2 Kits Required)TVS6DSPHC
Catalog NumberPeak Surge CurrentModule Catalog Number
"A" Phase
Module Catalog Number
"B" Phase
Module Catalog Number
"C" Phase
Diagnostic Cable
(3 per kit)
Front Display
(NEMA 1 SPDs only)
TVS6EMA48A480kAMA6IMA24 (2 Modules Required)MA6IMA24 (2 Modules Required)MA6IMA24 (2 Modules Required)TVS36PCK (2 Kits Required)TVS6DSPHC
TVS6EMA48ASWT480kAMA6IMA24 (2 Modules Required)MA6IMA24 (2 Modules Required)MA6IMA24 (2 Modules Required)TVS36PCK (2 Kits Required)TVS6DSPHC
TVS6EMA48A1480kAMA6IMA241 (2 Modules Required)MA6IMA241 (2 Modules Required)MA6IMA241 (2 Modules Required)TVS36PCK (2 Kits Required)TVS6DSPHC
TVS6EMA48AI480kAMA6IMA24 (2 Modules Required)MA6IMA24 (2 Modules Required)MA6IMA24 (2 Modules Required)TVS36PCK (2 Kits Required)TVS6DSPHC
TVS6EMA48AISWT480kAMA6IMA24 (2 Modules Required)MA6IMA24 (2 Modules Required)MA6IMA24 (2 Modules Required)TVS36PCK (2 Kits Required)TVS6DSPHC
TVS6EMA48AISWT1480kAMA6IMA241 (2 Modules Required)MA6IMA241 (2 Modules Required)MA6IMA241 (2 Modules Required)TVS36PCK (2 Kits Required)TVS6DSPHC
TVS6EMA48AI1480kAMA6IMA241 (2 Modules Required)MA6IMA241 (2 Modules Required)MA6IMA241 (2 Modules Required)TVS36PCK (2 Kits Required)TVS6DSPHC
TVS6EMA48S480kAMA6IMA24 (2 Modules Required)MA6IMA24 (2 Modules Required)MA6IMA24 (2 Modules Required)TVS36PCK (2 Kits Required)TVS6DSPHC
TVS6EMA48SI480kAMA6IMA24 (2 Modules Required)MA6IMA24 (2 Modules Required)MA6IMA24 (2 Modules Required)TVS36PCK (2 Kits Required)TVS6DSPHC
TVS6EMA48SSWT480kAMA6IMA24 (2 Modules Required)MA6IMA24 (2 Modules Required)MA6IMA24 (2 Modules Required)TVS36PCK (2 Kits Required)TVS6DSPHC
TVS6EMA48ASWT1480kAMA6IMA241 (2 Modules Required)MA6IMA241 (2 Modules Required)MA6IMA241 (2 Modules Required)TVS36PCK (2 Kits Required)TVS6DSPHC
TVS6EMA48SISWT480kAMA6IMA24 (2 Modules Required)MA6IMA24 (2 Modules Required)MA6IMA24 (2 Modules Required)TVS36PCK (2 Kits Required)TVS6DSPHC
TVS6EMA48S1480kAMA6IMA241 (2 Modules Required)MA6IMA241 (2 Modules Required)MA6IMA241 (2 Modules Required)TVS36PCK (2 Kits Required)TVS6DSPHC
TVS6EMA48SSWT1480kAMA6IMA241 (2 Modules Required)MA6IMA241 (2 Modules Required)MA6IMA241 (2 Modules Required)TVS36PCK (2 Kits Required)TVS6DSPHC
TVS6EMA48SI1480kAMA6IMA241 (2 Modules Required)MA6IMA241 (2 Modules Required)MA6IMA241 (2 Modules Required)TVS36PCK (2 Kits Required)TVS6DSPHC
TVS6EMA48SISWT1480kAMA6IMA241 (2 Modules Required)MA6IMA241 (2 Modules Required)MA6IMA241 (2 Modules Required)TVS36PCK (2 Kits Required)TVS6DSPHC

Surgelogic Label

To find your SPD part #, locate a white Surgelogic sticker on the interior of your SPD. This can typically be found on the sidewalls or on the door of the SPD. The label will look like the following:

spd

Schneider Electric USA

Explore more
Range:
Users group

Discuss this topic with experts

Visit our community and get advice from experts and peers on this topic and more
Explore more
Range:
  • Products Documentation
  • Software Downloads
  • Product Selector
  • Product Substitution and Replacement
  • Help and Contact Center
  • Where to buy
  • Get a Quote
  • Find our Offices
  • Schneider Electric Community
  • Careers
  • Company Profile
  • Report a misconduct
  • Accessibility
  • Newsroom
  • Investors
  • EcoStruxure
  • Job Search
  • Blog
  • Tech Support: 877-342-5173
  • Privacy Policy
  • Cookie Notice
  • Terms of use
  • Change your cookie settings