How can we help you today?

Why Does DI1 Show “Not Assigned” for Both Low and High in the I/O Map?

Resolution:

Go to Menu 5.5 – Command and Reference.Check the Control Mode setting.If the Control Mode is set to I/O Profile, the DI1 assignment will not display “Forward.”Change the Control Mode to Not Separate or Separate.Once updated, the DI1 assignment (for example, Forward) should appear correctly in the I/O Map.

If this article does not answer your question, check out our FAQ database that has answers to more commonly asked questions:

Frequently Asked Questions - Schneider Electric (se.com)

If this FAQ did not solve your issue, you can call us at 1-888-778-2733 Option 2 and then 4 or e-mail us atdrive.products.support@se.comto create a case with our Technical Support Team.

If you are not located in North America, please contact your local Customer Care Center for assistance:

Support | Schneider Electric Global (se.com)