Will Wiser Energy work with my solar panels?

Most likely! Your incoming solar feed can connect directly into your main electrical panel, either through a breaker or a service-side tap.

If solar is set up in a subpanel, the incoming solar feed should be within 46" of the main panel as this will allow the provided current sensor cable to reach and connect to the Wiser Energy monitor in the main electrical panel.

If it is further than 46" extension cables are available in lengths of;
Length(Feet)Part Number
4'WISEREMCTEXT4
12'WISEREMCTEXT12
25'WISEREMCTEXT25
40'WISEREMCTEXT40

These extensions can be combined to achieve larger lengths, but the maximum length can be no more than 300'.