How can we help you today?
What are the repair parts for an RC2040M150CH, Series M01?
Issue:
Repair parts
Product Line:
CSED
Resolution:
NOTE: WIRING DIAGRAM AND LABELS ARE NOT INCLUDED ON THE PARTS LISTED BELOW.
The parts listed here are the only parts considered field replaceable:
Meter Cover - 4056167850 (includes latch)
Load Center Cover - 4056157550 (includes hinges and latch)
Load Center Cover Mounting Screws - (4) 2159417121
Dead Front Interior Trim - 4056173901
Dead Front Interior Trim Mounting Screws - 4020513001K (contains 10 screws; only 2 are required)
Load Center Interior - 4056162050 (main breaker not included)
Load Center Interior Mounting Screws - (6) 2153217161
Main Breaker - QOM2150VH
Main Breaker Mounting Hardware - (2) 2342702001
Meter Base Assembly - 4056190050 (includes meter base, line side lugs, meter jaws, meter jaw blade guides, and horn bypasses)
Meter Jaw - (4) 7329794850
Meter Jaw Mounting Keps Nuts - (4) 2342702001
Meter Jaw Blade Guide - (4) 4052761901
Line Side Horn Bypasses - (2) 4056150901
Load Side Horn Bypass (Left) - 4052783101
Load Side Horn Bypass (Right) - 4052783102
Fifth Jaw Assembly - 4052797750
Fifth Jaw Assembly Mounting Screw - 2153217161
NOTE: WIRING DIAGRAM AND LABELS ARE NOT INCLUDED ON THE PARTS LISTED ABOVE.
Repair parts
Product Line:
CSED
Resolution:
NOTE: WIRING DIAGRAM AND LABELS ARE NOT INCLUDED ON THE PARTS LISTED BELOW.
The parts listed here are the only parts considered field replaceable:
Meter Cover - 4056167850 (includes latch)
Load Center Cover - 4056157550 (includes hinges and latch)
Load Center Cover Mounting Screws - (4) 2159417121
Dead Front Interior Trim - 4056173901
Dead Front Interior Trim Mounting Screws - 4020513001K (contains 10 screws; only 2 are required)
Load Center Interior - 4056162050 (main breaker not included)
Load Center Interior Mounting Screws - (6) 2153217161
Main Breaker - QOM2150VH
Main Breaker Mounting Hardware - (2) 2342702001
Meter Base Assembly - 4056190050 (includes meter base, line side lugs, meter jaws, meter jaw blade guides, and horn bypasses)
Meter Jaw - (4) 7329794850
Meter Jaw Mounting Keps Nuts - (4) 2342702001
Meter Jaw Blade Guide - (4) 4052761901
Line Side Horn Bypasses - (2) 4056150901
Load Side Horn Bypass (Left) - 4052783101
Load Side Horn Bypass (Right) - 4052783102
Fifth Jaw Assembly - 4052797750
Fifth Jaw Assembly Mounting Screw - 2153217161
NOTE: WIRING DIAGRAM AND LABELS ARE NOT INCLUDED ON THE PARTS LISTED ABOVE.
Released for: Schneider Electric USA
Explore more
Product:
Explore more
Product:
Need help?
Product Selector
Quickly and easily find the right products and accessories for your applications.
Get a Quote
Start your sales inquiry online and an expert will connect with you.
Where to buy?
Easily find the nearest Schneider Electric distributor in your location.
Help Center
Find support resources for all your needs, in one place.