What are the repair parts for the DTU362DS, series F5 (may be shown as F05) and series F6 (may be shown as F06)?
Issue:
Design Repair parts
Product Line:
Double Throw Safety Switch
Resolution:
The repair parts for the DTU362DS, series F5 (F05) and series F6(F06) are as follows. No other parts are available.
Line/Load Base assembly - 4056624250 (1 each upper and lower; order arc suppressor, load lugs, and wire assembly separately)
Line/Load Base mounting screws - 4020515101 (3 required per line base)
Arc Suppressor Assembly - 4056635550 (1 required per line base)
Arc Suppressor mounting screw - 4020514501 (1 required per arc suppressor)
Wire Assembly- 4056732650 (1 required per phase)
Line and/or Load Lug Assembly - 4025101652 (per lug)
Line and Load Lug mounting screw - 4020514202 (1 per lug)
Ground Lug - 4025101652 (per lug)
Ground Lug mounting screw - 4020513503 (1 per lug)
Switch Mechanism - 4056646950 (1 each for upper and lower)
Linkage Assembly - 4056665350 (also replace linkage assembly rubber gaskets)
Linkage Assembly Rubber Gaskets - 4050322801 (3 required)
Linkage Assembly mounting screws - 2142217101 (4 required) and 2194900001 (3 required); there are also gaskets used with the 3 outside screws, part number 4050322801
Handle - 4056688850
Lockplate - 4056689501
Lockplate mounting screws - 2194900001 (2 required)
Design Repair parts
Product Line:
Double Throw Safety Switch
Resolution:
The repair parts for the DTU362DS, series F5 (F05) and series F6(F06) are as follows. No other parts are available.
Line/Load Base assembly - 4056624250 (1 each upper and lower; order arc suppressor, load lugs, and wire assembly separately)
Line/Load Base mounting screws - 4020515101 (3 required per line base)
Arc Suppressor Assembly - 4056635550 (1 required per line base)
Arc Suppressor mounting screw - 4020514501 (1 required per arc suppressor)
Wire Assembly- 4056732650 (1 required per phase)
Line and/or Load Lug Assembly - 4025101652 (per lug)
Line and Load Lug mounting screw - 4020514202 (1 per lug)
Ground Lug - 4025101652 (per lug)
Ground Lug mounting screw - 4020513503 (1 per lug)
Switch Mechanism - 4056646950 (1 each for upper and lower)
Linkage Assembly - 4056665350 (also replace linkage assembly rubber gaskets)
Linkage Assembly Rubber Gaskets - 4050322801 (3 required)
Linkage Assembly mounting screws - 2142217101 (4 required) and 2194900001 (3 required); there are also gaskets used with the 3 outside screws, part number 4050322801
Handle - 4056688850
Lockplate - 4056689501
Lockplate mounting screws - 2194900001 (2 required)
Released for: Schneider Electric USA
Explore more
Product:
Explore more
Product:
Need help?
Product Selector
Quickly and easily find the right products and accessories for your applications.
Get a Quote
Start your sales inquiry online and an expert will connect with you.
Where to buy?
Easily find the nearest Schneider Electric distributor in your location.
Help Center
Find support resources for all your needs, in one place.