Is 256 volt replacement control coil available for LC1D15000?

Issue:
LC1D15000 Replacement coil of 256V Part number

Product Line:
IEC Contactors and Starters

Environment:
Tesys D Contactors

Resolution:
256 volt control is not an option on theses contactors. Average coil consumption is 300 VA inrush 22 VA sealed for 50 hertz, 300 VA inrush 22 VA sealed for 60 hertz and 280 to 350 VA inrush 2 to 18 VA sealed for 50/60 hertz.