Video: How to set PROFINET communication between Altivar and Siemens PLC's ?

Article available in these languages:

How to set PROFINET communication between Altivar and Siemens PLC's

This video explains How to set PROFINET communication between Altivar Drives and Siemens PLC’s using SoMove and TIA Portal.

Download the PROFINET GSDML file VW3A3627: https://www.se.com/fr/fr/download/document/PROFINET_GSDML_VW3A3627/

Download the latest version of Altivar ATV320 DTM here:
https://www.se.com/ww/en/download/document/ATV320_DTM_Library/

Download the latest version of Altivar ATV340 DTM here:
https://www.se.com/ww/en/download/document/ATV340_DTM_LibraryEN/

Download the latest version of Altivar ATV600 DTM here:
https://www.se.com/ww/en/download/document/ATV6xx_DTM_Library_EN//

Download the latest version of Altivar ATV900 DTM here:
https://www.se.com/ww/en/download/document/ATV9xx_DTM_Library_EN/


For more information see:
ATV600 PROFINET Manual - VW3A3627: https://www.se.com/ww/en/download/document/EAV64331/
ATV900  PROFINET Manual - VW3A3627: https://www.se.com/ww/en/download/document/NHA80943/
ATV340  PROFINET Manual - VW3A3627: https://www.se.com/ww/en/download/document/NVE61678/
ATV320  PROFINET Manual - VW3A3627: https://www.se.com/ww/en/download/document/NVE41311/

Languages add-on for ATV340 DTM:
https://www.se.com/ww/en/download/document/ATV340_DTM_Lang_FR/
https://www.se.com/ww/en/download/document/ATV340_DTM_Lang_CN/
https://www.se.com/ww/en/download/document/ATV340_DTM_Lang_IT/
https://www.se.com/ww/en/download/document/ATV340_DTM_Lang_SP/
https://www.se.com/ww/en/download/document/ATV340_DTM_Lang_DE/

Languages add-on for ATV600 DTM:
https://www.se.com/ww/en/download/document/ATV6xx_DTM_Lang_FR/
https://www.se.com/ww/en/download/document/ATV6xx_DTM_Lang_CN/
https://www.se.com/ww/en/download/document/ATV6xx_DTM_Lang_IT/
https://www.se.com/ww/en/download/document/ATV6xx_DTM_Lang_SP/
https://www.se.com/ww/en/download/document/ATV6xx_DTM_Lang_DE/

Languages add-on for ATV900 DTM:
https://www.se.com/ww/en/download/document/ATV9xx_DTM_Lang_FR/
https://www.se.com/ww/en/download/document/ATV9xx_DTM_Lang_CN/
https://www.se.com/ww/en/download/document/ATV9xx_DTM_Lang_IT/
https://www.se.com/ww/en/download/document/ATV9xx_DTM_Lang_SP/
https://www.se.com/ww/en/download/document/ATV9xx_DTM_Lang_DE/

Schneider Electric USA

Discuss this topic with experts

Visit our community and get advice from experts and peers on this topic and more

Explore more

Need help?

Product Selector

Quickly and easily find the right products and accessories for your applications.

Get a Quote

Start your sales inquiry online and an expert will connect with you.

Where to buy?

Easily find the nearest Schneider Electric distributor in your location.

Help Center

Find support resources for all your needs, in one place.