How can we help you today?

License Manager Integrity check failed

Issue:

When launching or installing License Manager an integrity check is reported and it does not open. The C:\Users\yourusername\AppData\Local\Temp\License Manager_reg.log shows signature problems on certain dlls.

Follow the steps below to update any certificates for .dll files that are listed as a problem in the License Manager_reg.log file.

1 - Run the following command(as Admin) to download the latest certificates in an SST file(requires internet, then you can transfer the file to the offline VM):

certutil.exe -generateSSTFromWU roots.sst

2- Open Powershell as admin and run the following commands: (You can open the roots.sst and install one by one the certificates that you require)

$sstStore = ( Get-ChildItem -Path <em>CertPath</em>\roots.sst)

$sstStore | Import-Certificate -CertStoreLocation Cert:\LocalMachine\Root

Example:

257920_IMG

Schneider Electric USA

Explore more
Range:
Users group

Discuss this topic with experts

Visit our community and get advice from experts and peers on this topic and more
Explore more
Range:
  • Help Center
  • Contact Sales
  • Find our Offices
  • Where to Buy
  • Tech Support: 877-342-5173
  • Careers
  • Company Profile
  • Investors
  • Newsroom
  • Report a Misconduct
  • Product Documentation
  • Software and Firmware
  • Product Selector
  • Product Replacement
  • DigestPLUS Online Catalog
  • Industries
  • Partners
  • Schneider Electric Community
  • Events
  • Privacy Policy
  • Cookie Notice
  • Terms of use
  • Change your cookie settings