How to open the hardware configuration on a HMI programmed with EOTE?

Issue

It is not clear how to open the hardware configuration on a physical HMI programmed with EcoStruxture Operator Terminal Expert

Product Line

EcoStruxture Operator Terminal Expert

HMI running EOTE, EOTE Runtime

Resolution

There are 2 options to try and open the hardware configuration on an HMI running EOTE

[Option 1]

Display with Touch Gestures

Within 0.5 seconds, touch the top-right then bottom-left corners, or the top-left and bottom-right corners (within a 40 pixel area) of the screen

Open the hardware configuration with gestures

This option can be enabled / disabled from the settings as follows.

1/ In the Project Explorer window, from [System Architecture] click [Target01].

2/ In the Properties window, go to [Function] tab ➞ [Options] tab ➞ [Preference].

Display Hardware Configuration option in EOTE

[Option 2]

Display with Hardware Configuration object on a screen

Note: The size of the object is the size of the Hardware Configuration screen. It is not a button.

Hardware Configuration Tool Part

If this FAQ did not solve your issue, you can chat with us at chat with us or e-mail us at customer.services@se.com to create a case with our Technical Support Team.

If you are not located in North America, please contact your local Customer Care Center for assistance:

Support | Schneider Electric Global (se.com)

Schneider Electric USA

Discuss this topic with experts

Visit our community and get advice from experts and peers on this topic and more

Explore more

Need help?

Product Selector

Quickly and easily find the right products and accessories for your applications.

Get a Quote

Start your sales inquiry online and an expert will connect with you.

Where to buy?

Easily find the nearest Schneider Electric distributor in your location.

Help Center

Find support resources for all your needs, in one place.