USA
Schneider Electric USA Website

Welcome to our website.

To view product availability in a specific country, select from the country list below. For Investor Relations, please visit our global site.

Select your location
View all Modicon Momentum
Schneider Eletric 171CCC98030 Picture
Discontinued

171CCC98030

Schneider Eletric 171CCC98030 Picture
Discontinued
171CCC98030

M1/M1E processor adaptor - 1 Ethernet, 1 Modbus - 50 MHz

Show more characteristics
171CCC98030171CCC98030  has not been replaced. Please contact your customer care center for more information.
  • Product availability
    Non-Stock - Not normally stocked in distribution facility
Add to My Products Remove from My Products
The maximum number of products that can be compared is 4

  • Main
    range of product
    Modicon Momentum automation platform
    product or component type
    M1/M1E processor adaptor
    concept
    Transparent Ready
    level or class
    Class B10
    software designation
    Concept V2.6
    Modsoft >= V2.5
    ProWORX NxT V2.0
    ProWORX 32
    communication port protocol
    Ethernet
    Modbus
    processor name
    X 86 based (INTEL, AMD) IEC executive
    clock frequency
    50 MHz
    Complementary
    web services
    Web page loader software tool
    Web page loader
    Rack viewer
    Data editor
    Ethernet service
    I/O scanning
    Modbus TCP messaging
    discrete I/O processor capacity
    8192 I/8192 O
    memory type
    1 MB flash
    544 kB RAM
    memory description
    Program memory 18 kB LL984
    Program memory 200 kB IEC
    Data 24 kB
    material
    Lexan
    word length
    16 bit
    [Us] rated supply voltage
    5.0 V DC +/-5 %
    supply
    By Momentum I/O base
    exact time for 1 Kinstruction
    1 ms
    register I/O processor capacity
    26048 I/26048 O
    I/O limit processor capacity
    I/O local on Modbus
    number of port
    1 RS485
    1 Ethernet
    marking
    CE
    net weight
    0.09 lb(US) (0.042 kg)
    Environment
    protective treatment
    TC
    ambient air temperature for operation
    32…140 °F (0…60 °C)
    ambient air temperature for storage
    -40…185 °F (-40…85 °C)
    relative humidity
    5…96 % without condensation
    operating altitude
    6561.68 ft (2000 m)
    shock resistance
    <= 15 gn peak 11 ms half sine wave acceleration
    vibration resistance
    0.75 mm d.a
    1 gn
    product certifications
    Nema type 250
    UL
    CUL
    FM Class 1 Division 2
    Ordering and shipping details
    Category
    18206 - MOMENTUM PROCESSORS,I/O BASES,CONN.
    Discount Schedule
    PC31
    GTIN
    00785901396383
    Package weight(Lbs)
    0.20 kg (0.45 lb(US))
    Returnability
    No
    Country of origin
    FR
    Contractual warranty
    Warranty
    18 months
  • View more View less

    Documents

    Language
    • English2
    Catalog
    Format
    Size
    Date
    Add to My Documents
    Modicon™ Quantum™ Ethernet I/O Automation Platform (Version 1.0)
    Description
    This catalog is a guide to Quantum™ Ethernet I/O and Unity™ Pro Software.
    Size pdf
    Size 6.4 MB
    Date 1/19/12
    Description
    This catalog is a guide to Quantum™ Ethernet I/O and Unity™ Pro Software.
    User guide
    Format
    Size
    Date
    Add to My Documents
    171CCC... / 171CCS... M1 Processor Adapter and Option Adapter (Version 10)
    Description
    This manual contains complete information about the Momentum M1 processor adapters, option adapters and Ethernet adapters. It does not contain information about Momentum I/O bases or communication adapters.
    Size pdf
    Size 3.6 MB
    Date 4/1/10
    Description
    This manual contains complete information about the Momentum M1 processor adapters, option adapters and Ethernet adapters. It does not contain information about Momentum I/O bases or communication adapters.
  • View more View less

    Software and Firmware

    Language
    • English2
    Firmware - Updates
    Format
    Size
    Date
    Add to My Documents
    171CCC9x0x0 Momentum M1E 984LL Exec. (Version 1.30)
    Files in document
    bin
    192 KB
    bin
    192 KB
    bin
    488 KB
    zip
    299.2 KB
    bin
    488 KB
    bin
    488 KB
    bin
    488 KB
    bin
    488 KB
    bin
    488 KB
    bin
    488 KB
    bin
    488 KB
    bin
    488 KB
    Description
    This 984LL firmware can be installed on any of the following Momentum PLCs: 171CCC96020 (984LL only) 171CCC98020 (984LL only) 171CCC96030 (IEC or 984LL) 171CCC98030 (IEC or 984LL)
    Size zip
    Size 5 MB
    Date 2/25/15
    Files in document
    bin
    192 KB
    bin
    192 KB
    bin
    488 KB
    zip
    299.2 KB
    bin
    488 KB
    bin
    488 KB
    bin
    488 KB
    bin
    488 KB
    bin
    488 KB
    bin
    488 KB
    bin
    488 KB
    bin
    488 KB
    Description
    This 984LL firmware can be installed on any of the following Momentum PLCs: 171CCC96020 (984LL only) 171CCC98020 (984LL only) 171CCC96030 (IEC or 984LL) 171CCC98030 (IEC or 984LL)
    171CCC9x030 Momentum M1E IEC Exec. (Version 1.31)
    Files in document
    bin
    488 KB
    bin
    488 KB
    bin
    488 KB
    bin
    488 KB
    bin
    488 KB
    bin
    488 KB
    bin
    488 KB
    bin
    488 KB
    bin
    488 KB
    bin
    488 KB
    bin
    488 KB
    bin
    488 KB
    Description
    **** Exec v1.31 for use with Concept 2.6 1) Added IEC cyclical application confidence checks Exec. v.1.30 (m1ev130e.bin) for use with Concept 2.6. Reference Resolution 192559. 1) M1E IEC Exec version 1.29 does not allow OFS to access Concept IEC unlocated variables. 2) An xxmit function block in a 171CCS78010 may fault with an error 150 under certain circumstances.
    Size zip
    Size 5.7 MB
    Date 2/25/15
    Files in document
    bin
    488 KB
    bin
    488 KB
    bin
    488 KB
    bin
    488 KB
    bin
    488 KB
    bin
    488 KB
    bin
    488 KB
    bin
    488 KB
    bin
    488 KB
    bin
    488 KB
    bin
    488 KB
    bin
    488 KB
    Description
    **** Exec v1.31 for use with Concept 2.6 1) Added IEC cyclical application confidence checks Exec. v.1.30 (m1ev130e.bin) for use with Concept 2.6. Reference Resolution 192559. 1) M1E IEC Exec version 1.29 does not allow OFS to access Concept IEC unlocated variables. 2) An xxmit function block in a 171CCS78010 may fault with an error 150 under certain circumstances.
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.
Compare products: /