View all
TeSys LRD Overload Relays

LR9D32KITD12BD
LR9D32KITD12BD
TESYS Motor Starter Kit, LC1D12BD Contactor, LR9D32 Thermal Overload Relay
Show more characteristics
* Price is “List Price” and may be subject to a trade discount – check with your local distributor or retailer for actual price.
-
Product availabilityNon-Stock - Not normally stocked in distribution facility
-
Characteristics
Main range TeSysproduct or component type Motor startercontactor application Resistive loadMotor controlutilisation category AC-1AC-4AC-3poles description 3Ppower pole contact composition 3 NO[Ue] rated operational voltage Power circuit <= 690 V AC 25...400 HzPower circuit <= 300 V DC[Ie] rated operational current 25 A 140 °F (60 °C)) <= 440 V AC AC-1 power circuit12 A 140 °F (60 °C)) <= 440 V AC AC-3 power circuitmotor power kW 3 kW 220...230 V AC 50/60 Hz AC-3)5.5 kW 380...400 V AC 50/60 Hz AC-3)5.5 kW 415...440 V AC 50/60 Hz AC-3)7.5 kW 500 V AC 50/60 Hz AC-3)7.5 kW 660...690 V AC 50/60 Hz AC-3)3.7 kW 400 V AC 50/60 Hz AC-4)motor power HP (UL / CSA) 0.5 hp 115 V AC 50/60 Hz 1 phase2 hp 230/240 V AC 50/60 Hz 1 phase3 hp 200/208 V AC 50/60 Hz 3 phase3 hp 230/240 V AC 50/60 Hz 3 phase7.5 hp 460/480 V AC 50/60 Hz 3 phase10 hp 575/600 V AC 50/60 Hz 3 phasecontrol circuit type DC standard[Uc] control circuit voltage 24 V DCauxiliary contact composition 1 NO + 1 NC[Uimp] rated impulse withstand voltage 6 kV IEC 60947overvoltage category III[Ith] conventional free air thermal current 25 A 140 °F (60 °C) power circuit10 A 140 °F (60 °C) signalling circuitIrms rated making capacity 250 A 440 V power circuit IEC 60947140 A AC signalling circuit IEC 60947-5-1250 A DC signalling circuit IEC 60947-5-1rated breaking capacity 250 A 440 V power circuit IEC 60947[Icw] rated short-time withstand current 105 A 104 °F (40 °C) - 10 s power circuit210 A 104 °F (40 °C) - 1 s power circuit30 A 104 °F (40 °C) - 10 min power circuit61 A 104 °F (40 °C) - 1 min power circuit100 A - 1 s signalling circuit120 A - 500 ms signalling circuit140 A - 100 ms signalling circuitassociated fuse rating 10 A gG signalling circuit IEC 60947-5-140 A gG <= 690 V type 1 power circuit25 A gG <= 690 V type 2 power circuitaverage impedance 2.5 mOhm - Ith 25 A 50 Hz power circuit[Ui] rated insulation voltage Power circuit 690 V IEC 60947-4-1Power circuit 600 V CSAPower circuit 600 V ULSignalling circuit 690 V IEC 60947-1Signalling circuit 600 V CSASignalling circuit 600 V ULelectrical durability 2 Mcycles 12 A AC-3 <= 440 V0.8 Mcycles 25 A AC-1 <= 440 Vpower dissipation per pole 0.36 W AC-31.56 W AC-1safety cover Withmounting support PlateRailstandards CSA C22.2 No 14EN 60947-4-1EN 60947-5-1IEC 60947-4-1IEC 60947-5-1UL 508product certifications BVCSADNVRINAGLGOSTLROS (Lloyds register of shipping)CCCULconnections - terminals Power circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)flexible without cable endPower circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²)flexible without cable endPower circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)flexible with cable endPower circuit screw clamp terminals 2 0.00…0.00 in² (1…2.5 mm²)flexible with cable endPower circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)solid without cable endPower circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²)solid without cable endControl circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)flexible without cable endControl circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²)flexible without cable endControl circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)flexible with cable endControl circuit screw clamp terminals 2 0.00…0.00 in² (1…2.5 mm²)flexible with cable endControl circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)solid without cable endControl circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²)solid without cable endtightening torque Power circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals flat Ø 6 mmPower circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals Philips No 2Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals flat Ø 6 mmControl circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals Philips No 2operating time 53.55...72.45 ms closing16...24 ms openingsafety reliability level B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1mechanical durability 30 Mcyclesmaximum operating rate 3600 cyc/h 140 °F (60 °C)relay application Motor protectionphase failure sensitivity Phase difference > 40% 3 s IEC 60947-4-1Complementary coil technology With integral suppression devicecontrol circuit voltage limits Drop-out 0.1...0.25 Uc DC 140 °F (60 °C))Operational 0.7...1.25 Uc DC 140 °F (60 °C))time constant 28 msinrush power in W 5.4 W 68 °F (20 °C))hold-in power consumption in W 5.4 W 68 °F (20 °C)auxiliary contacts type Mechanically linked 1 NO + 1 NC IEC 60947-5-1Mirror contact 1 NC IEC 60947-4-1signalling circuit frequency 25...400 Hzminimum switching current 5 mA signalling circuitminimum switching voltage 17 V signalling circuitnon-overlap time 1.5 ms on de-energisation between NC and NO contact1.5 ms on energisation between NC and NO contactinsulation resistance > 10 MOhm signalling circuitcontact compatibility M4motor power range 4…6 kW 380…440 V 3 phase4…6 kW 480…500 V 3 phase2.2…3 kW 200…240 V 3 phasemotor starter type Direct on-line contactorcontactor coil voltage 24 V DC standardthermal overload class Class 5…30thermal protection adjustment range 6.4…32 Amaximum power consumption in W 300 mWmounting support Under contactorPlate, with specific accessoriesRail, with specific accessories[Ue] rated operational voltage 690 V power circuit660 V signalling circuit[Ui] rated insulation voltage Power circuit 1000 VSignalling circuit 690 Vtripping threshold 1.25 In IEC 60947-4-1control type Red push-button stop and manual resetWhite 2 microswitches adjustable trip classRed knob automatic resetGrey dial full-load current adjustmenttime range 1.5...4 min - automatic reset time[Ith] conventional free air thermal current 5 A signalling circuitassociated fuse rating 5 A gG signalling circuit5 A BS signalling circuit[Uimp] rated impulse withstand voltage 6 kVIP degree of protection Front face IP20 IEC 60529Front face IP20 VDE 0106mechanical robustness Vibrations 10...150 Hz 6 Gn) IEC 60068-2-6Shocks 11 ms 15 gn) IEC 60068-2-7connections - terminals Control circuit screw clamp terminals 1 0.00 in² (2.5 mm²) solid or flexible - without cable endPower circuit screw clamp terminals 1 0.02 in² (16 mm²) solid or flexible - without cable endtightening torque Control circuit 0.8 N.m screw clamp terminalsPower circuit 3.1 N.m screw clamp terminalsEnvironment IP degree of protection IP20 front face IEC 60529protective treatment TH IEC 60068-2-30pollution degree 3ambient air temperature for operation 23…140 °F (-5…60 °C)permissible ambient air temperature around the device -40…158 °F (-40…70 °C) at Ucoperating altitude 9842.52 ft (3000 m) withoutmechanical robustness Vibrations contactor open2 Gn, 5...300 HzVibrations contactor closed4 Gn, 5...300 HzShocks contactor open10 Gn for 11 msShocks contactor closed15 Gn for 11 msheight 3.03 in (77 mm)width 1.77 in (45 mm)depth 3.74 in (95 mm)net weight 1.07 lb(US) (0.485 kg)standards UL 60947-4-1IEC 60947-4-1CSA C22.2GB 14048.4product certifications CSACCCTÜVCULusambient air temperature for operation -13…158 °F (-25…70 °C) IEC 60255-8ambient air temperature for storage -76…176 °F (-60…80 °C)ambient air temperature for storage -67…176 °F (-55…80 °C)operating altitude 6561.68 ft (2000 m) without deratingfire resistance 1562 °F (850 °C) IEC 60695-2-1flame retardance V1 UL 94electromagnetic compatibility Surge withstand 2 kV common mode IEC 61000-4-5Resistance to electrostatic discharge 8 kV IEC 61000-4-2Immunity to radiated radio-electrical interference 10 V/m IEC 61000-4-3Immunity to fast transients 2 kV IEC 61000-4-4dielectric strength 6 kV 50 Hz IEC 60255-5height 2.85 in (72.5 mm)width 1.77 in (45 mm)depth 3.15 in (79.9 mm)net weight 0.40 lb(US) (0.18 kg)Ordering and shipping details Category 22350 - LR9D AND TESYS D STARTER KITSDiscount Schedule I12Package weight(Lbs) 0.74 kg (1.64 lb(US))Returnability YesCountry of origin CNOffer Sustainability REACh Regulation REACh free of SVHC YesEU RoHS Directive Compliant
EU RoHS DeclarationToxic heavy metal free YesMercury free YesRoHS exemption information China RoHS Regulation China RoHS declaration
Pro-active China RoHS declaration (out of China RoHS legal scope)WEEE The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins. -
View more
Documents
Language- English3
China RoHS declarationFormatSizeAdd to My DocumentsLR9D32KITD12BD_ROHS_CHINA_DECLARATIONDescriptionLR9D32KITD12BD_ROHS_CHINA_DECLARATIONSize pdfSize 195.3 KBDate 12/8/19DescriptionLR9D32KITD12BD_ROHS_CHINA_DECLARATIONEU RoHS DeclarationFormatSizeAdd to My DocumentsLR9D32KITD12BD_ROHS_DECLARATIONDescriptionLR9D32KITD12BD_ROHS_DECLARATIONSize pdfSize 195.3 KBDate 12/8/19DescriptionLR9D32KITD12BD_ROHS_DECLARATIONREACh DeclarationFormatSizeAdd to My DocumentsLR9D32KITD12BD_REACH_DECLARATIONDescriptionLR9D32KITD12BD_REACH_DECLARATIONSize pdfSize 195.3 KBDate 12/8/19DescriptionLR9D32KITD12BD_REACH_DECLARATION -
Technical FAQs
No results found.Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.