Characteristics
Main range TeSysproduct name TeSys LRDproduct or component type Electronic thermal overload relaydevice short name LR9Drelay application Motor protectionproduct compatibility LC1D150NSX circuit breakerLC1D115network type ACsignalling function Alarmthermal protection adjustment range 60…100 A[Ui] rated insulation voltage Power circuit 1000 V IEC 60947-4-1Power circuit 600 V CSAPower circuit 600 V ULComplementary network frequency 50...60 Hz[Us] rated supply voltage 24 V DCsupply voltage limits 17…32 Vmounting support Under contactorRailtripping threshold 1.05 +/- 0.06 In alarm IEC 60947-4-11.12 +/- 0.06 In de-energisation IEC 60947-4-1[Ith] conventional free air thermal current 5 A signalling circuit[Ue] rated operational voltage 690 V 50...60 Hzassociated fuse rating 5 A gG signalling circuit[Uimp] rated impulse withstand voltage 6 kV IEC 61000-4-5phase failure sensitivity Tripping in 4 s +/- 20 % IEC 60947-4-1control type Red push-button stopBlue push-button resettemperature compensation -4…140 °F (-20…60 °C)switching capacity in mA 0...150 mAmaximum voltage drop <2.5 V closed stateconnections - terminals Power circuit barsControl circuit screw clamp terminals 1 0.00…0.00 in² (0.5…1.5 mm²) flexible without cable endControl circuit screw clamp terminals 2 0.00…0.00 in² (0.5…1.5 mm²) flexible without cable endAlarm circuit screw clamp terminals 1 0.00…0.00 in² (0.5…1.5 mm²) flexible without cable endtightening torque Alarm circuit 3.98 lbf.in (0.45 N.m) screw clamp terminalsPower circuit 159.31 lbf.in (18 N.m) bars M8Control circuit 10.62 lbf.in (1.2 N.m) screw clamp terminalsdepth 5.20 in (132 mm)net weight 1.95 lb(US) (0.885 kg)Environment protective treatment TH IEC 60068IP degree of protection IP20 IEC 60529ambient air temperature for operation -4…140 °F (-20…60 °C) without derating IEC 60947-4-1ambient air temperature for storage -76…158 °F (-60…70 °C)operating altitude <= 6561.68 ft (2000 m) without deratingmechanical robustness Vibrations2 Gn, 5...300 Hz IEC 60068-2-6Shocks13 Gn for 11 ms IEC 60068-2-7dielectric strength 6 kV 50 Hz IEC 60255-5standards IEC 60947-4-1EN 60947-4-1IEC 255-8IEC 255-17VDE 0660product certifications CSA 22-2UL 508Ordering and shipping details Category 22347 - CONTACTOR,D-LINE,OVERLOADS-NEWDiscount Schedule I12GTIN 00785901435426Package weight(Lbs) 0.99 kg (2.19 lb(US))Returnability YesCountry of origin FROffer Sustainability Sustainable offer status Green Premium productCalifornia proposition 65 WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide which is known to the State of California to cause Carcinogen harm. For more information go to www.p65warnings.ca.govREACh Regulation EU RoHS Directive Compliant
EU RoHS DeclarationMercury free YesRoHS exemption information China RoHS Regulation China RoHS declaration
Product out of China RoHS scope. Substance declaration for your information.Environmental Disclosure Circularity Profile WEEE The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.Contractual warranty Warranty 18 months -
View more
Documents
Language- All Languages17
- English18
- Chinese8
- French9
- German8
- Russian8
- Spanish8
CatalogFormatSizeAdd to My DocumentsDigest 178 Catalog 18: Contactors and Starters-IEC (Version 1.0)DescriptionSection 18 of Digest 178 provides selection and ordering information for IEC contactors and starters - TeSys K, TeSys D, TeSys F, TeSys U, TeSys GV, and TeSys LS1. Replaces Digest 177 section 18; 0100CT1501_SEC-18Size pdfSize 6.8 MBDate 9/13/19DescriptionSection 18 of Digest 178 provides selection and ordering information for IEC contactors and starters - TeSys K, TeSys D, TeSys F, TeSys U, TeSys GV, and TeSys LS1. Replaces Digest 177 section 18; 0100CT1501_SEC-18TeSys catalogue - 2019 - 2020 - chapter B11 Overload relays TeSys LRK, LRD, LR9, RM1, LT3 (Version 7.0)DescriptionThermal overload relays : TeSys LRK, LRDElectronic thermal overload relays : TeSys LR9, LR9FSIgnle pole overcurrent relay : TeSys RM1PTC-type protection relay: TeSys LT3Size pdfSize 5.5 MBDate 5/15/19DescriptionThermal overload relays : TeSys LRK, LRDElectronic thermal overload relays : TeSys LR9, LR9FSIgnle pole overcurrent relay : TeSys RM1PTC-type protection relay: TeSys LT3Data BulletinFormatSizeAdd to My DocumentsMotor Control Solutions for the North American Market (Version 2.0)DescriptionThis bulletin contains information regarding the application of solutions to meet your motor control and protection needs in the US and Canada.Size pdfSize 1.5 MBDate 2/10/17DescriptionThis bulletin contains information regarding the application of solutions to meet your motor control and protection needs in the US and Canada.CADFormatSizeAdd to My DocumentsCAD for LR9D5567: TeSys LRD thermal overload relays - 60...100 A - class 20 (Version 1.0)DescriptionYou will be redirected to the ThomasNet website. Then you could download this CAD model in more than 15 different 2D or 3D CAD formats.CAD for LR9D5567: TeSys LRD thermal overload relays - 60...100 A - class 20 (Version 1.0)DescriptionYou will be redirected to the ThomasNet website. Then you could download this CAD model in more than 15 different 2D or 3D CAD formats.TeSys D Differential thermal overload relays Class 10, 10A or 20 for connection by bars or connectors (Version 1.0)Files in documentSize zipSize 1.1 MBDate 4/2/14Files in documentCertificateFormatSizeAdd to My DocumentsInstruction SheetFormatSizeAdd to My DocumentsSize pdfSize 2.7 MBDate 5/1/15China RoHS declarationFormatSizeAdd to My DocumentsLR9D5567_ROHS_CHINA_DECLARATIONDescriptionLR9D5567_ROHS_CHINA_DECLARATIONSize pdfSize 195.3 KBDate 12/7/19DescriptionLR9D5567_ROHS_CHINA_DECLARATIONDeclaration of conformityFormatSizeAdd to My DocumentsSize pdfSize 290.2 KBDate 7/18/19End of Life InformationFormatSizeAdd to My DocumentsEU RoHS DeclarationFormatSizeAdd to My DocumentsLR9D5567_ROHS_DECLARATIONDescriptionLR9D5567_ROHS_DECLARATIONSize pdfSize 195.3 KBDate 12/7/19DescriptionLR9D5567_ROHS_DECLARATIONProduct Environmental ProfileFormatSizeAdd to My DocumentsREACh DeclarationFormatSizeAdd to My DocumentsLR9D5567_REACH_DECLARATIONDescriptionLR9D5567_REACH_DECLARATIONSize pdfSize 195.3 KBDate 12/7/19DescriptionLR9D5567_REACH_DECLARATION -
Technical FAQs
No results found.Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.