Schneider Electric USA Website

Welcome to our website.

Select your location

View all   Zelio Control
Schneider Eletric RM35BA10 Picture

RM35BA10

Green premium brand logo
Schneider Eletric RM35BA10 Picture
RM35BA10
Green premium brand logo

pump control relay RM35-BA - range 1..10 A

Show more characteristics
  • Product availability
    Non-Stock - Not normally stocked in distribution facility
  • 284.00 USD
    Price is “List Price” and may be subject to a trade discount – check with your local distributor or retailer for actual price.
The maximum number of products that can be compared is 4. Remove already added products.

  • Main
    range of product
    Zelio Control
    product or component type
    Modular measurement and control relays
    relay type
    Pump control relays
    product specific application
    For 3-phase and single-phase pump
    relay name
    RM35BA
    relay monitored parameters
    Overcurrent and undercurrent control
    Phase sequence on 3-phase supply
    Phase failure on 3-phase supply
    time delay type
    Adjustable 1...60 s, +/- 10 % Ti on energisation
    Fixed 0.3 s reset on terminal Y2
    Adjustable 0.1...10 s, +/- 10 % Tt on crossing the threshold
    switching capacity in VA
    1250 VA
    minimum switching current
    10 mA 5 V DC
    maximum switching current
    5 A AC/DC
    maximum power consumption in VA
    5 VA AC
    measurement range
    1...10 A AC
    utilisation category
    AC-12 IEC 60947-5-1
    AC-13 IEC 60947-5-1
    AC-14 IEC 60947-5-1
    AC-15 IEC 60947-5-1
    DC-12 IEC 60947-5-1
    DC-13 IEC 60947-5-1
    Complementary
    reset time
    2000 ms
    maximum switching voltage
    250 V AC/DC
    [Un] rated nominal voltage
    208...480 V AC 3 phase
    230 V AC single phase
    [Un] rated nominal voltage
    208...480 V AC 3 phase
    230 V AC 1 phase
    supply voltage limits
    183…528 V AC
    operating voltage tolerance
    - 15 % + 10 % Un
    resistance across terminals
    0.01 Ohm E1-L2 terminals
    width
    1.38 in (35 mm)
    output contacts
    1 C/O
    nominal output current
    5 A
    maximum measuring cycle
    140 ms as true rms value
    delay at power up
    0.5 s
    hysteresis
    5 % threshold
    measurement accuracy
    +/- 10 % of the full scale value
    repeat accuracy
    +/- 1 % input and measurement circuit
    +/- 1 % time delay
    measurement error
    1 % by volt over the whole range
    +/- 0.05 %/°C
    response time
    < 300 ms in the event of a fault)
    overload input current
    11 A permanent at 25 °C E1-L2 terminals
    50 A non repetitive < 1 s at 25 °C E1-L2 terminals
    marking
    CE : EMC 89/336/EEC
    CE : 73/23/EEC
    overvoltage category
    III IEC 60664-1
    insulation resistance
    > 500 MOhm 500 V DC between supply and relay output 60255-5
    > 500 MOhm 500 V DC between measurement and relay output 60664-1
    > 1 MOhm 500 V DC between supply and measurement 60255-5
    > 500 MOhm 500 V DC between supply and relay output 60664-1
    > 500 MOhm 500 V DC between measurement and relay output 60255-5
    > 1 MOhm 500 V DC between supply and measurement 60664-1
    [Ui] rated insulation voltage
    400 V IEC 60664-1
    supply frequency
    50/60 Hz +/- 10 %
    operating position
    Any position
    connections - terminals
    Screw terminals, 1 x 0.5...1 x 4 mm² AWG 20...AWG 11) solid without cable end
    Screw terminals, 2 x 0.5...2 x 2.5 mm² AWG 20...AWG 14) solid without cable end
    Screw terminals, 1 x 0.2...1 x 2.5 mm² AWG 24...AWG 12) flexible with cable end
    Screw terminals, 2 x 0.2...2 x 1.5 mm² AWG 24...AWG 16) flexible with cable end
    tightening torque
    5.31…8.85 lbf.in (0.6…1 N.m) IEC 60947-1
    housing material
    Self-extinguishing plastic
    status LED
    1 LED Green power ON
    1 LED Yellow fault
    1 LED Yellow relay ON
    mounting support
    35 mm symmetrical DIN rail EN/IEC 60715
    electrical durability
    100000 cycles
    mechanical durability
    30000000 cycles
    operating rate
    <= 360 operations/hour full load
    Environment
    immunity to microbreaks
    500 ms
    electromagnetic compatibility
    Emission standard for industrial environments EN/IEC 61000-6-4
    Emission standard for residential, commercial and light-industrial environments EN/IEC 61000-6-3
    Immunity for industrial environments NF EN/IEC 61000-6-2
    standards
    EN/IEC 60255-6
    product certifications
    C-tick
    CSA
    GOST
    UL
    GL
    ambient air temperature for storage
    -40…158 °F (-40…70 °C)
    ambient air temperature for operation
    -4…122 °F (-20…50 °C)
    relative humidity
    95 % 131 °F (55 °C) IEC 60068-2-30
    vibration resistance
    0.35 mm 5…57.6 Hz)IEC 60068-2-6/IEC 60255-21-1
    1 gn 57.6…150 Hz)IEC 60068-2-6/IEC 60255-21-1
    shock resistance
    15 gn 11 ms IEC 60255-21-1
    IP degree of protection
    IP20 IEC 60529 terminals)
    IP30 IEC 60529 casing)
    pollution degree
    3 IEC 60664-1
    dielectric strength
    2 kV AC 50 Hz shock wave 4 kV)
    Ordering and shipping details
    Category
    22380 - RELAYS-MEASUREMENT (RM17-RM35)
    Discount Schedule
    CP2
    GTIN
    00785901637417
    Returnability
    No
    Country of origin
    ID
    Offer Sustainability
    Sustainable offer status
    Green Premium product
    California proposition 65
    WARNING: This product can expose you to chemicals including: Lead and lead compounds which is known to the State of California to cause Carcinogen & Reproductive harm. For more information go to www.p65warnings.ca.gov
    REACh Regulation
    EU RoHS Directive
    Pro-active compliance (Product out of EU RoHS legal scope)
    EU RoHS Declaration
    Mercury free
    Yes
    RoHS exemption information
    China RoHS Regulation
    Environmental Disclosure
    Circularity Profile
    WEEE
    The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    Contractual warranty
    Warranty
    18 months
  • View more View less

    Documents

    Language
    • All Languages18
    • English17
    • French4
    • German3
    • Italian3
    • Spanish3
    Catalog
    Format
    Size
    Date
    Add to My Documents
    prp.document.label.format pdf
    Size 8.1 MB
    Date 6/24/19
    prp.document.label.format pdf
    Size 6 MB
    Date 5/12/19
    prp.document.label.format pdf
    Size 7.1 MB
    Date 6/24/19
    Certificate
    Format
    Size
    Date
    Add to My Documents
    prp.document.label.format pdf
    Size 3 MB
    Date 5/23/19
    UL Listed RM17, RM22, RM35, RM8487 (Version 1.0)
    Files in document
    pdf
    475.7 KB
    pdf
    473.4 KB
    prp.document.label.format zip
    Size 949 KB
    Date 5/19/15
    Files in document
    pdf
    475.7 KB
    pdf
    473.4 KB
    prp.document.label.format htm
    Size 213 B
    Date 5/18/15
    Instruction Sheet
    Format
    Size
    Date
    Add to My Documents
    prp.document.label.format pdf
    Size 523.5 KB
    Date 4/1/19
    China RoHS declaration
    Format
    Size
    Date
    Add to My Documents
    RM35BA10 : pump control relay RM35-BA - range 1..10 A
    Description
    pump control relay RM35-BA - range 1..10 A
    prp.document.label.format pdf
    Size 195.3 KB
    Date 5/26/20
    Description
    pump control relay RM35-BA - range 1..10 A
    End of Life Information
    Format
    Size
    Date
    Add to My Documents
    prp.document.label.format pdf
    Size 5.4 MB
    Date 5/1/19
    prp.document.label.format pdf
    Size 89.6 KB
    Date 2/1/16
    prp.document.label.format pdf
    Size 582.8 KB
    Date 11/1/11
    EU RoHS Declaration
    Format
    Size
    Date
    Add to My Documents
    RM35BA10 : pump control relay RM35-BA - range 1..10 A
    Description
    pump control relay RM35-BA - range 1..10 A
    prp.document.label.format pdf
    Size 195.3 KB
    Date 5/26/20
    Description
    pump control relay RM35-BA - range 1..10 A
    Product Environmental Profile
    Format
    Size
    Date
    Add to My Documents
    prp.document.label.format pdf
    Size 5.4 MB
    Date 5/1/19
    prp.document.label.format pdf
    Size 3.3 MB
    Date 1/1/16
    prp.document.label.format pdf
    Size 2.2 MB
    Date 11/1/11
    REACh Declaration
    Format
    Size
    Date
    Add to My Documents
    RM35BA10 : pump control relay RM35-BA - range 1..10 A
    Description
    pump control relay RM35-BA - range 1..10 A
    prp.document.label.format pdf
    Size 195.3 KB
    Date 5/26/20
    Description
    pump control relay RM35-BA - range 1..10 A
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.
  • Dimensions Drawings

    3-Phase and Single-Phase Pump Control Relays
    Dimensions and Mounting



  • Connections and Schema

    3-Phase and Single-Phase Pump Control Relays
    Wiring Diagrams

    3-phase < 10 A


    Single-phase ∼ 230 V < 10 A


    3-phase > 10 A


    Single-phase ∼ 230 V > 10 A



  • Technical Description

    Function Diagrams
    Single Control Mode

    This mode is designed to control a pump via an external signal. The relay output is closed when the signal is present at Y1 (contact closed). Y2 can be used to reset the relay after a current fault.


    Double Control Mode

    This mode is designed to control a pump via two external control signals (Y1 and Y2). The output relay closes when both input signals are present (Y1 and Y2 closed).


    Current Control

    If the control relay is configured for a single-phase supply, it monitors the current consumed by the pump. If the control relay is configured for a 3-phase supply, it monitors the current, phase sequence and phase failure.

    Overcurrent detection


    Undercurrent Detection


    Legend

    Ti Time delay to inhibit fault monitoring on starting of pump

    Tt Time delay in the event of a fault

    Un 3-phase or single-phase power supply

    I Monitored current

    I < Undercurrent threshold

    I > Overcurrent threshold

    I. Def Presence of a current fault

    11-12, 11-14 Output relay connections

    Relay status: black color = energized.