USA
Schneider Electric USA Website

Welcome to our website.

To view product availability in a specific country, select from the country list below. For Investor Relations, please visit our global site.

Select your location
View all Modicon Premium PAC
Schneider Eletric TSXESF08T22 Picture
Discontinued

TSXESF08T22

Schneider Eletric TSXESF08T22 Picture
Discontinued
TSXESF08T22

discrete output module - 2 groups of 4 outputs - 24 V DC - IP67

Show more characteristics
TSXESF08T22TSXESF08T22  has not been replaced. Please contact your customer care center for more information.
  • Price*
    1,145.00 USD
Add to My Products Remove from My Products
The maximum number of products that can be compared is 4

  • Main
    range of product
    Modicon Premium Automation platform
    product or component type
    Discrete output module on Fipio
    discrete I/O number
    8
    group of channels
    2 groups of 4 outputs
    Complementary
    power supply monitoring
    14…18 V DC preactuator
    discrete output number
    8
    discrete output type
    Solid state
    discrete output voltage
    24 V DC
    output voltage limits
    19.2...30 V
    discrete output current
    2 A
    maximum output current
    2.5 A 140 °F (60 °C) per channel
    4.8 A 104 °F (40 °C) per group of 4 channels
    8 A per group of 4 channels
    maximum leakage current
    1 mA at state 0
    [Ures] residual voltage
    0.5 V at state 1 on output
    response time on output
    < 0.5 ms resistive
    short-circuit protection
    4.5 A by thermal circuit breaker on output
    output overload protection
    4.5 A by thermal circuit breaker on output
    output overvoltage protection
    By transil diode
    isolation between channels
    None
    isolation voltage
    500 V AC between bus and internal logic
    isolation between output channels group
    60 Vrms AC
    isolation between channels and internal logic
    60 Vrms AC
    local signalling
    Module operation and integrated communication 3 LEDs
    Channels status 8 LEDs
    Preactuator power supply 2 LEDs
    electrical connection
    1 connector dust and damp proof male M23 for Fipio bus connctn, 24V DC power supply for sensor & internal electric of mod
    1 connector male 7/8 inch for 2 24 V DC preactuators power supplies
    8 connectors female M12 for connecting preactuator
    operating position
    Any position
    marking
    CE
    current consumption
    130 mA 24 V DC 5 two-wire sensor inputs and 5 outputs at state 1
    net weight
    1.19 lb(US) (0.54 kg)
    Environment
    IP degree of protection
    IP67
    weatherproofness level
    Dust and damp proof
    ambient air temperature for operation
    32…140 °F (0…60 °C)
    ambient air temperature for storage
    -13…158 °F (-25…70 °C)
    operating altitude
    0...6561.68 ft (0...2000 m)
    shock resistance
    15 gn 11 ms
    standards
    DIN
    EN/IEC 61131
    CNOMO
    product certifications
    Fipio
    UL
    CSA
    Ordering and shipping details
    Category
    22558-TSX PREMIUM, ATRIUM & PL7 PRO
    Discount Schedule
    PC22
    GTIN
    03595862046831
    Package weight(Lbs)
    1.44 lb(US) (0.652 kg)
    Returnability
    No
    Country of origin
    DE
    Contractual warranty
    Warranty
    18 months
  • View more View less

    Documents

    Language
    • All Languages3
    • English1
    • French1
    • Spanish1
    User guide
    Format
    Size
    Date
    Add to My Documents
    Premium and Atrium Using EcoStruxure™ Control Expert - IP67 Sealed Input/Output Modules, Setup Manual (Version 11)
    Description
    This manual describes the implementation of hardware and software for IP67 sealed input/output modules with Premium and Atrium PLCs.
    Size pdf
    Size 1.1 MB
    Date 12/1/18
    Description
    This manual describes the implementation of hardware and software for IP67 sealed input/output modules with Premium and Atrium PLCs.
    Premium et Atrium sous EcoStruxure™ Control Expert - Modules d’entrées/sorties étanches IP67, Manuel de configuration (Version 11)
    Description
    Ce manuel décrit la mise en oeuvre matérielle et logicielle des modules d'entrées/sorties étanches IP67 pour les automates Premium et Atrium.
    Size pdf
    Size 1.2 MB
    Date 12/1/18
    Description
    Ce manuel décrit la mise en oeuvre matérielle et logicielle des modules d'entrées/sorties étanches IP67 pour les automates Premium et Atrium.
    Premium y Atrium con EcoStruxure™ Control Expert - Módulos de entradas/salidas selladas IP67, Manual de configuración (Version 11)
    Description
    En este manual se describe la instalación del hardware y del software de los módulos de entradas/salidas selladas IP67 para los PLC Premium y Atrium.
    Size pdf
    Size 1.2 MB
    Date 12/1/18
    Description
    En este manual se describe la instalación del hardware y del software de los módulos de entradas/salidas selladas IP67 para los PLC Premium y Atrium.
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.
  • Dimensions Drawings

    IP 67 Module
    Dimensions

    Horizontal dimensions


    Vertical dimensions including TSXEFACC•••• connector



  • Mounting and Clearance

    Installation Principles

    The input or output modules can be mounted side-by-side, whilst maintaining a distance of 87 mm/3.42 in. in between the axes of consecutive modules.


    The use of a T connection for the output power supplies requires a minimum distance of 87 mm/3.42 in. in between two modules.



    Mounting
    Location of Drill Holes



  • Connections and Schema

    Connection of Module Outputs

    Each output of the module uses an M12 connector (one output per connector).


    M12 connector


    1

    Not Connected

    2

    Not Connected

    3

    0 Vdc

    4

    2 A output

    5

    Ground

    Actuator wiring:


    7/8" connector.


    1

    24 Vdc (US1)

    2

    24 Vdc (US2)

    3

    Ground

    4

    0 V (US1)

    5

    0 V (US2)

    For the outputs to operate correctly, the two 24 Vdc power supplies (US1 and US2) shall be connected to the module via the output power supply connector:

    • the outputs 16, 17, 18 and 19 are powered by the US1 power supply,

    • the outputs 20, 21, 22 and 23 are powered by the US2 power supply.