You are currently viewing the content available in Vietnam. If you are looking for information for another region, please select the correct country from the top-left dropdown in the page and 'Navigate to Browse FAQs' in the Support menu.
Issue:
File writes or program installation to the main drive of a Magelis iPC are not being kept before and after a restart because the disk volume is write-protected.
Product Line:
Magelis iPC, HMIG5U22, HMIG5U21
Environment:
Windows 10 IoT Enterprise 32bit
Resolution:
1. First, go to the Start Menu (aka Windows Icon) and navigate to Schneider Electric – Utilities -> UWF Change
2. Press the YES Button.

3. To deactivate/activate the UWF, toggle the off/on switch and press OK.


4. Press the YES Button

File writes or program installation to the main drive of a Magelis iPC are not being kept before and after a restart because the disk volume is write-protected.
Product Line:
Magelis iPC, HMIG5U22, HMIG5U21
Environment:
Windows 10 IoT Enterprise 32bit
Resolution:
1. First, go to the Start Menu (aka Windows Icon) and navigate to Schneider Electric – Utilities -> UWF Change
2. Press the YES Button.
3. To deactivate/activate the UWF, toggle the off/on switch and press OK.
4. Press the YES Button
Released for:Schneider Electric Vietnam