Naše značky

Vítejte na internetových stránkách společnosti Schneider Electric

Vítejte na našich internetových stránkách.
		
Jak vám dnes můžeme pomoci?
Material Safety Data Sheets (MSDS) or Safety data Sheets (SDS) for Batteries Used in APC UPS 1 Phase Systems

Issue:

I require the Material Safety Data Sheet (MSDS) or Safety Data Sheet (SDS)  for various APC single phase UPS products.


Product Line:

All APC Single phase UPS


Environment:

All APC UPS


Cause:

The majority of batteries used in APC by Schneider Electric Uninterruptible Power Supply (UPS) systems and Replacement Battery Cartridges (RBCs) are contained within cartridges and are sealed, non-spillable, maintenance-free lead acid batteries. The batteries are a manufactured article consisting of a plastic, sealed case, terminals and flame arrestor vent caps. Case color varies. The electrolyte is contained within the case and consists of the electrolyte held captive in an adsorbed glass mat (AGM) or gel matrix. There is no “free” electrolyte to leak out of the case. Under normal use and handling, there is no contact with the internal components of the battery or the chemical hazards. Under normal use and handling, these products do not emit regulated or hazardous substances. The design life of a sealed lead acid battery is 3-5 years depending on environmental factors. Using the batteries past the end of it’s design life can result in electrolyte leakage.

In a few cases, Replacement Battery Cartridges (RBCs) containing High Power Lithium Ion Cell, Phosphate-Based are also used. These batteries are used stricitly in select models found in the Back-UPS Connect family.

Resolution:

North America

UPS

Battery

MSDS

Back UPS, Smart UPS, Easy UPS, Symmetra LX, Symmetra RMAll VRLA RBC, SYBT2, SYBT5Click Here

Smart UPS Line Interactive Lithium Ion

UPS

Battery

MSDS

UN38.3

SCL500RM1NC / SCL500RM1UC / SCL500RM1UNCN/AClick HereClick Here
SMTL750RM2UC / SMTL1000RM2UC / SMTL1500RM2UC N/AClick HereClick Here
SMTL2200RMXXX / SMT2K2RMXXX / SMT3000RMXXX / SMT3KRMXXXAPCRBC174-LIClick HereClick Here

Smart UPS Ultra

UPS

Battery

MSDS

UN38.3

SRTL2K2RM1UC / SRTL2K2RM1UNC / SRTL3KRM1UNC / SRTL3KRM1UWCAPCRBC173-LIClick HereClick Here
SRTL50RMBP1U-LIN/AClick HereClick Here
Smart UPS Ultra 5K-10K / SRTL180RM2UBP /  Smart UPS Modular UltraSRYLBMClick HereClick Here

Easy UPS Online Lithium Ion

UPS

Battery

MSDS

UN38.3

SRVSL1KRARK / SRVSL2K2RARK / SRVSL3KRARKRBCV181-LI / RBCV182-LI / RBCV183-LIClick HereClick Here
SRVL48RMBP2U N/AClick HereClick Here
SRVL48RMBP3UN/AClick HereClick Here

Schneider Off-Grid

UPS

Battery

MSDS

UN38.3

PPS330N/AClick HereClick Here
PPS500N/AClick HereClick Here
PPS730N/AClick HereClick Here

Microsoft Surface Hub 2S & Surface Hub 3

UPS

Battery

MSDS

UN38.3

CSH2Click HereClick Here

EU / International

UPS

Battery

MSDS

Back UPS, Smart UPS, Easy UPS, Symmetra LX, Symmetra RMAll VRLA RBC, SYBT2, SYBT5Click Here

Smart UPS Line Interactive Lithium Ion

UPS

Battery

MSDS

UN38.3

SCL500RMI1UC / SCL500RMI1UNCN/AClick HereClick Here
SMTL750RMI2UC / SMTL1000RMI2UC / SMTL1500RMI2UC N/AClick HereClick Here
SMTL2200RMIXXX / SMT2K2RMIXXX / SMT3000RMIXXX / SMT3KRMIXXXAPCRBC174-LIClick HereClick Here

Smart UPS Online Lithium Ion

UPS

Battery

MSDS

UN38.3

SRTL1000RMXLI / SRTL1500RMXLIXBP48RM1U-LIClick HereClick Here
SRTL2200RMXLI / SRTL3000RMXLIXBP48RM1U2-LIClick HereClick Here
SRTL1000RM4UXLI / SRTL1500RM4UXLI / SRTL2200RM4UXLI / SRTL3000RM4UXLIXBP48RM2U-LIClick HereClick Here

Smart UPS Ultra

UPS

Battery

MSDS

UN38.3

SRTL2K2RM1UIC / SRTL2K2RM1UINC / SRTL3KRM1UINC / SRTL3KRM1UICAPCRBC173-LIClick HereClick Here
SRTL50RMBP1U-LIN/AClick HereClick Here
Smart UPS Ultra 5K-10K / SRTL180RM2UBP SRYLBMClick HereClick Here

Easy UPS Online Lithium Ion

UPS

Battery

MSDS

UN38.3

SRVL1KRIRK / SRVSL1KRIRK / SRVL2K2RIRK / SRVSL2K2RIRK / SRVL3KRIRK / SRVSL3KRIRKRBCV181-LI / RBCV182-LI / RBCV183-LIClick HereClick Here
SRVL48RMBP2UN/AClick HereClick Here
SRVL48RMBP3UN/AClick HereClick Here

Schneider Off-Grid

UPS

Battery

MSDS

UN38.3

PPS330N/AClick HereClick Here
PPS500N/AClick HereClick Here
PPS730N/AClick HereClick Here

Microsoft Surface Hub 2S & Surface Hub 3

UPS

Battery

MSDS

UN38.3

CSH2N/AClick HereClick Here

APC Back UPS Connect

UPS

Battery

MSDS

UN38.3

CP12036LIN/AClick HereClick Here

Schneider Electric Česká republika

  • Dokumentace k produktům
  • Software ke stažení
  • Nástroj pro výběr produktů
  • Hledání náhrady za produkty
  • Centrum nápovědy a kontakty
  • Najít naše pobočky
  • Získejte nabídku
  • Kde koupit
  • Komunita Schneider Electric
  • Kariéra
  • Profil společnosti
  • Nahlásit nevhodné chování
  • Přístupnost
  • Newsroom
  • Investoři
  • EcoStruxure
  • Vyhledávání pracovních míst
  • Blog
  • Zásady ochrany osobních údajů
  • Oznámení o souborech cookie
  • Podmínky použití
  • Změnit nastavení souborů cookie