{}

Naše značky

Impact-Company-Logo-English Black-01-177x54

Vítejte na internetových stránkách společnosti Schneider Electric

Vítejte na našich internetových stránkách.
Jak vám dnes můžeme pomoci?
Spare parts list for ACRD1XX, and ACRD2XX

Article available in these languages: Španělština

Issue:
ACRD1XX and ACRD2XX spare parts list.

Product line:
ACRD1XX, ACRD2XX.

Environment:
All Serial Numbers.

Cause:
Most popular spare parts list.

Resolution:
Please contact Cooling Tech Support to confirm the part numbers before quoting as some may have changed. 888-695-6500 Option 2, Option 2, Option 2
ACRD 10KW SPARE PARTS SKU'SIndividual Item Spares
Shipping Weights & Measures Summary
Item NumberDescriptionShipping Weight (kg)Shipping Height (mm)Shipping Width (mm)Shipping Depth (mm)Part Weight (kg)Part Height (mm)Part Width (mm)Part Depth (mm)
W0H-0212CONNECTOR SET CUSTOMER INTERFACE - SPARE PART 0.079 110.0 110.0 110.0 0.035 155.0 100.0 10.0
W0M-61370FRONT DOOR ASSY 10 KW - SPARE PART 9.600 195.0 2,000.0 380.0 5.450 69.0 1,917.0 297.0
W0N-7166CONDENSATE PUMP ASSY - 110V-240V - SPARE PART 0.340 160.0 160.0 160.0 0.205 30.0 45.0 165.0
W0P2566COMPLETE 829 PCB CRAC PWR BACKPLANE - SPARE PART 0.883 200.0 440.0 260.0 0.129 45.0 327.0 80.0
W0P2570CRAC 8X 2 FORM-C RELAY - SPARE PART 0.373 180.0 225.0 210.0 0.099 32.0 180.0 48.0
W0W4440WIRE ASSEMBLY CTRLR SIG - SPARE PART 0.797 190.0 320.0 270.0 0.497 50.0 320.0 270.0
W0W4441WIRE ASSEMBLY AC10KW BASE FEATURES - SPARE PART 2.505 210.0 310.0 330.0 1.956 50.0 310.0 330.0
W0W4442WIRE ASSEMBLY PWR TO CTRLR BOX - SPARE PART 0.177 160.0 160.0 160.0 0.054 50.0 160.0 160.0
W0W4444WIRE ASSEMBLY PBP PWR - SPARE PART 0.582 190.0 310.0 260.0 0.271 50.0 310.0 260.0
W0W4446WIRE ASSEMBLY MB NTC JMPR - SPARE PART 0.071 110.0 110.0 110.0 0.024 50.0 110.0 110.0
W234-0500CAP MTL PPR 370V 50UF - SPARE PART
W234-1700CAP MTL PPR 370V 70UF - SPARE PART
W451-0241CONTACTOR DP 2 POLE 30A 208-240V - SPARE PART 0.293 110.0 110.0 110.0 0.236 60.0 90.0 65.0
W875-00094UNION 3/4" STRAIGHT C X C - SPARE PART 0.315 110.0 110.0 110.0 0.270 47.0 47.0 56.0
W875-00100BRAZED PLATE HX WPH24-40 - SPARE PART 7.980 240.0 490.0 220.0 7.051 460.0 90.0 130.0
W875-00103COMP, SCROLL 208-230/1/60, 10KW, DANFOSS - SPARE PART 42.000 610.0 900.0 450.0 31.900 480.0 290.0 300.0
W875-00105VALVE ELECTRONIC EXPANSION SER6 3/8" ODF - SPARE PART 0.607 160.0 160.0 160.0 0.446 160.0 163.0 150.0
W875-00108COIL SOLENOID VALVE 1/2" 208-240V 7W DIN - SPARE PART 0.172 110.0 110.0 110.0 0.114 50.0 35.0 35.0
W875-00112GASKET UNION 3/4" - SPARE PART 0.057 110.0 110.0 110.0 0.080 11.0 40.0 40.0
W875-2088FILTER-DRIER 1/2"ODF SOLDER - SPARE PART 0.780 160.0 160.0 160.0 0.692 200.0 80.0 80.0
W875-3882COMP, SCROLL 220-240/1/50, 10KW, DANFOSS - SPARE PART 42.500 610.0 900.0 450.0 32.140 480.0 290.0 300.0
W875-4350VALVE SOLENOID BODY REFRIGERATION 1/2" ODF - SPARE PART 0.265 160.0 160.0 160.0 0.102 70.0 85.0 30.0
W875-4357VALVE TXV 1/2"ODM X 5/8" ODF EXTENDED, R410A 3 TON - SPARE PART 0.656 160.0 160.0 160.0 0.561 160.0 110.0 85.0
W920-0082DC RECTIFIER 500W - SPARE PART 2.493 214.0 130.0 332.0 2.013 130.0 72.0 275.0

Schneider Electric Česká republika

Přílohy
ACRD 10KW Spare SKUS rev1.xls [71 KB]
ACRDXXX Spare Part List.xlsx [73.02 KB]
Zjistěte více
Řada:
Užitečné články
Zjistěte více
Řada: