What is the Nomenclature for Common Relays

Issue:
User wants to know the abbreviations for common relay types.

Resolution:

  • Normally Open (NO) contacts connect the circuit when the relay is activated; the circuit is disconnected when inactive. This type is also called Form A or a make contact.
  • Normally Closed (NC) contacts disconnect the circuit when the relay is activated; the circuit is connected when inactive. This type is also called Form B or a break contact.
  • Change-over (Double-Throw) contacts control two circuits: one NO and one NC contact with a common terminal. This type is called Form C or a transfer contact. It is often “break-before-make.” The opposite, “make-before-break,” is Form D.

Other common relay types:

  • SPST (Single Pole Single Throw): Two terminals that can be connected or disconnected. With coil terminals, there are four total. Contact can be NO or NC; abbreviations SPNO and SPNC clarify this.
  • SPDT (Single Pole Double Throw): One common terminal connects to either of two others. With coil terminals, there are five total.
  • DPST (Double Pole Single Throw): Two pairs of terminals, equivalent to two SPST relays operated by one coil. Six terminals total.
  • DPDT (Double Pole Double Throw): Two rows of change-over terminals, equivalent to two SPDT relays operated by one coil. Eight terminals total.
  • 4PDT (Four Pole Double Throw)/Quadruple Pole Double Throw (QTDP) : Four rows of change-over terminals, equivalent to four SPDT relays or two DPDT relays operated by one coil. Fourteen terminals total.


Diagrams

Schneider Electric Česká republika

  • Dokumentace k produktům
  • Software ke stažení
  • Nástroj pro výběr produktů
  • Hledání náhrady za produkty
  • Centrum nápovědy a kontakty
  • Najít naše pobočky
  • Získejte nabídku
  • Kde koupit
  • Komunita Schneider Electric
  • Kariéra
  • Profil společnosti
  • Nahlásit nevhodné chování
  • Přístupnost
  • Newsroom
  • Investoři
  • EcoStruxure
  • Vyhledávání pracovních míst
  • Blog
  • Zásady ochrany osobních údajů
  • Oznámení o souborech cookie
  • Podmínky použití
  • Změnit nastavení souborů cookie