Naše značky

Vítejte na internetových stránkách společnosti Schneider Electric

Vítejte na našich internetových stránkách.
		
Jak vám dnes můžeme pomoci?
PowerLogic PM5000 Series Technical datasheet, Brochure and Part number breakdown

Article available in these languages: Francouzština, Nizozemština

Product Line
PM5110, PM5330, PM5340, PM5560, and PM5563

Environment
Specifications, Functions and Characteristics, Dimensions
Feature and Capability, Comparison Table, Part number

Resolution
See attached documents for the technical datasheet, Brochure, and part number breakdown details.

Refer to Article FA234023 for Installation and User Guide.

Refer to Article FA234017 for Register List.

NOTE: The Technical Datasheet document contains global models as well.

The table below shows the catalog number for ordering the meter in North America, for any new part numbers mentioned in the technical data sheet please contact technical support for more information.
ModelCatalog NumberDescription
PM5110METSEPM5110Basic metering with class 0.5S accuracy + pulse output & serial communications
PM5330METSEPM5330Basic metering with class 0.5S accuracy + 2DI/2DO + data logging + multi tariff + serial communications + 2 relay (form A)
PM5340METSEPM5340Basic metering with class 0.5S accuracy + 2DI/2DO + data logging + multi tariff + Ethernet + 2 relay (form A)
PM5560METSEPM5560Basic metering with class 0.2S accuracy + 4DI/2DO + data logging + multi tariff + dual Ethernet and serial COMs + 4th CT input for neutral & ground measurement + internal web server.   (Gateway + Cyber Security Added)
PM5563METSEPM5563Basic metering with class 0.2S accuracy + 4DI/2DO + data logging + multi tariff + dual Ethernet and serial COMs + 4th CT input for neutral & ground measurement + internal web server - DIN Rail meter with no display.
PM5563RDMETSEPM5563RDBasic metering with class 0.2S accuracy + 4DI/2DO + data logging + multi tariff + dual Ethernet and serial COMs + 4th CT input for neutral & ground measurement + internal web server - Remote Display and DIN Rail meter.
PM5RDMETSEPM5RDPM5500 series remote display – 5RD for Remote display 96 x 96 mm monochrome

Schneider Electric Česká republika

Přílohy
PM5XXX technical data sheet.pdf [491.55 KB]
PM5000_part_numbers_breakdown.pdf [117.28 KB]
PM5000_US_Brochure.pdf [3.09 MB]
Zjistěte více
Řada:
Zjistěte více
Řada:
  • Dokumentace k produktům
  • Software ke stažení
  • Nástroj pro výběr produktů
  • Hledání náhrady za produkty
  • Centrum nápovědy a kontakty
  • Najít naše pobočky
  • Získejte nabídku
  • Kde koupit
  • Komunita Schneider Electric
  • Kariéra
  • Profil společnosti
  • Nahlásit nevhodné chování
  • Přístupnost
  • Newsroom
  • Investoři
  • EcoStruxure
  • Vyhledávání pracovních míst
  • Blog
  • Zásady ochrany osobních údajů
  • Oznámení o souborech cookie
  • Podmínky použití
  • Změnit nastavení souborů cookie