Jak vám dnes můžeme pomoci?
How to add a dependency to a service
Issue
No existing user interface to add a dependency to a service once created.
Product Line
Any software that uses Windows Services
Environment
Windows Server 2008
Windows Server 2012
Windows Server 2016
Windows 7
Cause
A user wants to add a dependency to an existing service.
Resolution
Steps in this article require knowing the service name.
This can be found in services.msc by right clinking on the desired service and selecting properties.
The name desired is the field "Service name"
1) Open a command prompt as administrator.
2) To list current dependencies, type the following command where ServiceA is the name of the service you want to add a dependency:
sc qc ServiceA
3) To add multiple dependencies, type the following command where Service B,C,D are services to add as a dependency for ServiceA:
sc config ServiceA depend= ServiceB/ServiceC/ServiceD
The command above means that ServiceA will not start until ServiceB, ServiceC, and ServiceD have all started. If you stop any of ServiceB, ServiceC, or ServiceD, ServiceA will stop automatically.
4) To remove all dependencies, type the following command:
sc config ServiceA depend= /
No existing user interface to add a dependency to a service once created.
Product Line
Any software that uses Windows Services
Environment
Windows Server 2008
Windows Server 2012
Windows Server 2016
Windows 7
Cause
A user wants to add a dependency to an existing service.
Resolution
Steps in this article require knowing the service name.
This can be found in services.msc by right clinking on the desired service and selecting properties.
The name desired is the field "Service name"
1) Open a command prompt as administrator.
2) To list current dependencies, type the following command where ServiceA is the name of the service you want to add a dependency:
sc qc ServiceA
3) To add multiple dependencies, type the following command where Service B,C,D are services to add as a dependency for ServiceA:
sc config ServiceA depend= ServiceB/ServiceC/ServiceD
The command above means that ServiceA will not start until ServiceB, ServiceC, and ServiceD have all started. If you stop any of ServiceB, ServiceC, or ServiceD, ServiceA will stop automatically.
4) To remove all dependencies, type the following command:
sc config ServiceA depend= /
Publikováno pro: Schneider Electric Česká republika
Potřebujete pomoc?
Nástroj pro výběr produktů
Rychle a snadno vyhledávejte správné produkty a příslušenství pro vaše aplikace.
Získejte nabídku
Poptejte se nás online a náš lokální specialista se s vámi spojí!
Kde nakoupit?
Jednoduše najděte nejbližšího distributora výrobků Schneider Electric ve vašem okolí.
Centrum nápovědy
Zdroje podpory pro všechny své potřeby najdete na jednom místě.