Issue:
Can you get a pulse output on a variable speed drive?
Product Line:
Altivar Machines, Altivar 340
Environment:
All models and serial number
Cause:
Pulse output needed for signal sent back to PLC
Resolutuon:
The ATV340 product has a PTO (Pulse Train Output) available on connector CN4.
It is a 5Vdc differential RS422 signal with the output frequency greater than or equal to 500 kHz.
Can you get a pulse output on a variable speed drive?
Product Line:
Altivar Machines, Altivar 340
Environment:
All models and serial number
Cause:
Pulse output needed for signal sent back to PLC
Resolutuon:
The ATV340 product has a PTO (Pulse Train Output) available on connector CN4.
It is a 5Vdc differential RS422 signal with the output frequency greater than or equal to 500 kHz.
Publikováno pro:Schneider Electric Česká republika

