How to completely remove Vijeo Designer Runtime from a PC
Issue
How does one completely remove Vijeo Designer Runtime from a PC?
Product Line
Vijeo Designer Runtime
VJDSNRTMPC
VJDSNRTSPC
VJDRPCCZLSPMZZ
VJDRPCCZLSPAZZ
VJDHPCCZLSPMZZ
VJDHPCCZLSPAZZ
Environment
HMI Runtime software for Windows PC
Resolution
To bring the PC to a state with Vijeo Designer Runtime completely removed, there are two methods available.
Method 1 (the Windows Uninstaller Method):
Uninstall Vijeo Designer Runtime from Windows "Add/Remove Programs". Looking for Vijeo Runtime and then choose Uninstall.
Method 2 (Deletion of Files):
1) Delete the folder and the contents of the folder:
C:\Program Files (x86)\Schneider Electric\Vijeo-Designer\Vijeo-Runtime\
(on older 32bit Windows PCs):
C:\Program Files\Schneider Electric\Vijeo-Designer\Vijeo-Runtime\
2) From the folder "C:\Windows\", delete the file named "57340"
3) Delete the Registry folders (if they exist):
Computer\HKEY_LOCAL_MACHINE\SOFTWARE\WOW6432Node\Schneider Electric\Vijeo-Designer\
Computer\HKEY_LOCAL_MACHINE\SOFTWARE\WOW6432Node\Schneider Electric\Vijeo-Designer Runtime\
Computer\HKEY_LOCAL_MACHINE\SOFTWARE\WOW6432Node\Schneider Electric\Vijeo-Designer-Runtime-PC-V2020 (this folder exists for 6.2 SP11+)
(on older 32bit Windows PCs):
Computer\HKEY_LOCAL_MACHINE\SOFTWARE\Schneider Electric\Vijeo-Designer\
Computer\HKEY_LOCAL_MACHINE\SOFTWARE\Schneider Electric\Vijeo-Designer Runtime\
If this FAQ did not solve your issue, you can chat with us at chat with us or e-mail us at customer.services@se.com to create a case with our Technical Support Team.
If you are not located in North America, please contact your local Customer Care Center for assistance:
Publikováno pro: Schneider Electric Česká republika
Zjistěte více
Řada:
Zjistěte více
Řada:
Potřebujete pomoc?
Nástroj pro výběr produktů
Rychle a snadno vyhledávejte správné produkty a příslušenství pro vaše aplikace.
Získejte nabídku
Poptejte se nás online a náš lokální specialista se s vámi spojí!
Kde nakoupit?
Jednoduše najděte nejbližšího distributora výrobků Schneider Electric ve vašem okolí.
Centrum nápovědy
Zdroje podpory pro všechny své potřeby najdete na jednom místě.