Naše značky

Vítejte na internetových stránkách společnosti Schneider Electric

Vítejte na našich internetových stránkách.
		
Jak vám dnes můžeme pomoci?
Are there any StruxureWare DCE version limitations to newer Dell servers now used ?
Issue:

StruxureWare DCE versions may be limited by newer hardware

Product Line:

InfraStruxure Central
StruxureWare Data Center Expert

Environment:

Versions specified below

Cause:

Due to certain servers no longer being sold by Dell, we have had to upgrade to newer versions of hardware. In some cases, newer drivers may be necessary.

Resolution:

To include new drivers to support the newer servers, new versions of ISXC or DCE were created. Older versions may not install properly on the newer hardware.

The following lists the specific servers and their required minimum software version:
  • Dell R710: 6.0.1 or higher
  • Dell R210: 6.1.1 or higher
  • Dell R210-II: 6.1.1 or higher
  • Dell R720: 7.2.1 or higher
  • Dell R740: 7.6 or higher. (may see getSystemId error on boot of system)
  • Dell R250: 7.9.2 or higher due to UEFI requirement.

Schneider Electric Česká republika

Zjistěte více
Řada:
Zjistěte více
Řada:
  • Dokumentace k produktům
  • Software ke stažení
  • Nástroj pro výběr produktů
  • Hledání náhrady za produkty
  • Centrum nápovědy a kontakty
  • Najít naše pobočky
  • Získejte nabídku
  • Kde koupit
  • Komunita Schneider Electric
  • Kariéra
  • Profil společnosti
  • Nahlásit nevhodné chování
  • Přístupnost
  • Newsroom
  • Investoři
  • EcoStruxure
  • Vyhledávání pracovních míst
  • Blog
  • Zásady ochrany osobních údajů
  • Oznámení o souborech cookie
  • Podmínky použití
  • Změnit nastavení souborů cookie