How to Add a Video to a PME Dashboard
Issue
How to configure and play a video in a PME dashboard.
Product
Power Monitoring Expert 7.2
Power Monitoring Expert 8.x
Power Monitoring Expert 9.x
Power Monitoring Expert 2021
Power Monitoring Expert 2022
Power Monitoring Expert 2023
Power Monitoring Expert 2024
Environment
PME Dashboard
Cause
Customize a PME dashboard to display and play a video.
Resolution
After adding a Web Viewer gadget to a dashboard, the Source setting on the Content tab can be configured in one of two methods depending on the location of the video.
If the video is publicly accessible, the Source parameter of the Web Viewer gadget can be configured to use the URL that links directly to the video.
Example: https://www.youtube.com/embed/9JkFCkp6hmk
If you would like your video to autoplay in dashboards, add the Autoplay parameter to the end of URL. After the URL add the following text ?autoplay=1
It should now look like this: https://www.youtube.com/embed/9JkFCkp6hmk?autoplay=1
If the video is not publicly accessible, another option is to create a folder called \media on the PME server
under …\\Applications\ApplicationFramework and save the video at that location.
The Source parameter of the Web Viewer gadget can then be configured to the URL, http://web/media/
Publikováno pro: Schneider Electric Česká republika
Zjistěte více
Řada:
Zjistěte více
Řada:
Potřebujete pomoc?
Nástroj pro výběr produktů
Rychle a snadno vyhledávejte správné produkty a příslušenství pro vaše aplikace.
Získejte nabídku
Poptejte se nás online a náš lokální specialista se s vámi spojí!
Kde nakoupit?
Jednoduše najděte nejbližšího distributora výrobků Schneider Electric ve vašem okolí.
Centrum nápovědy
Zdroje podpory pro všechny své potřeby najdete na jednom místě.