Jak vám dnes můžeme pomoci?
How to View the Details of a Active Directory User Account
Issue
How to display the detailed information of an Active Directory User's account.
Product
Power Monitoring Expert 8.x
Power Monitoring Expert 9.x
Power Monitoring Expert 2020
Power Monitoring Expert 2021
Power Monitoring Expert 2022
Power Monitoring Expert 2023
Power Monitoring Expert 2024
Environment
Windows Active Directory
Cause
While troubleshooting an suspected permissions or configuration issue, it may be necessary to view and verify a particular Active Directory User's account information in order to determine there are no issues with the account and/or the account has been configured with appropriate parameters. (i.e. the password has not expired or recently been changed and the User has been included in the appropriate groups)
Resolution
From a computer that is a member of the domain, open a command-prompt and run the following command replacing <user name> with the name
of the user you are interested in.NET USER "<user name>" /DOMAIN
This same command can retrieve the local computer user account information as well by removing the /DOMAIN parameterand providing the name of a local user's account.
Publikováno pro: Schneider Electric Česká republika
Zjistěte více
Produkt:
Zjistěte více
Produkt:
Potřebujete pomoc?
Nástroj pro výběr produktů
Rychle a snadno vyhledávejte správné produkty a příslušenství pro vaše aplikace.
Získejte nabídku
Poptejte se nás online a náš lokální specialista se s vámi spojí!
Kde nakoupit?
Jednoduše najděte nejbližšího distributora výrobků Schneider Electric ve vašem okolí.
Centrum nápovědy
Zdroje podpory pro všechny své potřeby najdete na jednom místě.